IBM Support

OA64139: ABND=U2049,RSN=6E2B94C3,CL_AIO_ERROR+01EE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The z/OS NFS Client abnormally terminates with
    ABND=U2049,RSN=6E2B94C3,cl_aio_error+01EE
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of the z/OS NFS client who         *
    *                 encounter the User ABEND of U2049 in         *
    *                 GFSCRTHD module.                             *
    ****************************************************************
    * PROBLEM DESCRIPTION: The User ABEND is triggered because of  *
    *                      the insufficient serialization when the *
    *                      z/OS NFS client schedules the 1st       *
    *                      AIO_RECV upon handling AIO_CONNECT      *
    *                      completion.                             *
    ****************************************************************
    Obtain the proper serialization.
    

Problem conclusion

  • Obtain the necessary serialization since the first scheduled
    AIO_RECV can immediately fail (due to AT-TLS handshake failure).
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA64139

  • Reported component name

    NETWORK FILE SY

  • Reported component ID

    5695DF121

  • Reported release

    25N

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-12-08

  • Closed date

    2023-02-14

  • Last modified date

    2023-03-10

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UJ92175 UJ92184

Modules/Macros

  • GFSCRTHD
    

Fix information

  • Fixed component name

    NETWORK FILE SY

  • Fixed component ID

    5695DF121

Applicable component levels

  • R24N PSY UJ92184

       UP23/02/24 P F302 ¢

  • R25N PSY UJ92175

       UP23/02/24 P F302 ¢

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.