A fix is available
APAR status
Closed as program error.
Error description
CKR1952 24 CKRPUTV: Invalid element length for SRCIP For example: CKR1952 24 CKRPUTV: Invalid element length 000000001AEFC1E0 for 1B57F2B0 SRCIP defined at CKRCARLA(CKQLEEFL) line 1596
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: Users of zSecure Audit processing SMF * * reports. * **************************************************************** * PROBLEM DESCRIPTION: zSecure Audit might issue a MSGCKR1952 * * while processing SMF data containing * * DB2 Instrumentation Facility Component * * Identifier 319 (Audit Security) * * records. * **************************************************************** * RECOMMENDATION: Apply the PTF provided. * **************************************************************** When zSecure Audit processes SMF data containing DB2 Instrumentation Facility Component Identifier 319 (Audit Security) records (SMF record type 102) and the SRCIP SMF field is specified for reporting, the program might issue a MSGCKR1952 which begins with the text "CKRPUTV: Invalid element...". The RECORDDESC SMF field for these records reports an unreadable TCP/IP address.
Problem conclusion
zSecure Audit has been modified, so that it processes the DB2 Instrumentation Facility Component Identifier 319 (Audit Security) records (SMF record type 102) correctly.
Temporary fix
Comments
APAR Information
APAR number
OA63882
Reported component name
ZSEC BASE,ADMIN
Reported component ID
5655T0100
Reported release
250
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-11-04
Closed date
2022-11-18
Last modified date
2022-12-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ09541
Modules/Macros
CKADB2 GKRDB2
Fix information
Fixed component name
ZSEC BASE,ADMIN
Fixed component ID
5655T0100
Applicable component levels
R250 PSY UJ09541
UP22/11/19 P F211
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSPQTM","label":"IBM Security zSecure Admin"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"250","Line of Business":{"code":"LOB24","label":"Security Software"}}]
Document Information
Modified date:
01 December 2022