A fix is available
APAR status
Closed as new function.
Error description
INGPLEX LOGRY / LOGRZ and System Recovery Boost support
Local fix
n/a
Problem summary
**************************************************************** * USERS AFFECTED: All IBM Z System Automation V4R2 and * * V4R3 customers using CDS types LOGRY and * * LOGRZ or System Recovery Boost (SRB). * **************************************************************** * PROBLEM DESCRIPTION: Single-system couple data set types * * LOGRY and LOGRZ should be supported. * **************************************************************** In z/OS V2.4, support for two new system logger couple data sets was added specifically to support the GDPS KSYS requirements where the couple data sets have to reside on disks that are isolated from the rest of the production systems. Since there are two KSYS systems in a DR environment, this required to have two additional separate CDS types, LOGRY and LOGRZ. The INGPLEX CDS command should support the new CDS typed. The INGPLEX SYS display should show the current System Recovery Boost (SRB) status.
Problem conclusion
Temporary fix
Comments
Changes have been made to implement the enhancements listed above. For more information, refer to these links: https://ibm.biz/SA42Enhancements https://ibm.biz/SA43Enhancements
APAR Information
APAR number
OA63831
Reported component name
SYSTEM AUTO Z/O
Reported component ID
5698SA300
Reported release
430
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-09-22
Closed date
2022-11-04
Last modified date
2022-12-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ09577 UJ09578 UJ09579 UJ09580 UJ09581 UJ09582
Modules/Macros
AOF91 AOF94 AOFE AOFF#POL AOFFBGRP AOFFCPTF AOFFCREL AOFFGPB0 AOFFPMAN AOFFZTBL AOFGGPB0 AOFHGPB0 AOFJ AOFKX100 AOFRACF7 AOFRVX10 AOFRX100 AOFSGRP5 AOFTLP1 ING#PLEX INGCJBSP INGCJISP INGCJPSP INGH$PLX INGKX312 INGPECAP INGRVX30 INGRVX31 INGRVX9U INGRX300 INGRX301 INGRX312 INGRX319 INGRX720 INGSPJAR
Fix information
Fixed component name
SYSTEM AUTO Z/O
Fixed component ID
5698SA300
Applicable component levels
R420 PSY UJ09580
UP22/11/09 P F211
R421 PSY UJ09582
UP22/11/09 P F211
R42F PSY UJ09581
UP22/11/09 P F211
R430 PSY UJ09577
UP22/11/09 P F211
R431 PSY UJ09579
UP22/11/09 P F211
R43F PSY UJ09578
UP22/11/09 P F211
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSWRCJ","label":"Tivoli System Automation for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"430","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
01 December 2022