Error description

  • After an AGMQ INIT Mxxx (where Mxxx is the MQ queue manager),
    zAPM starts monitoring the MQ subsystem. This creates an
    entry in an APM control block associated with the SSCT. The
    APM control block supports 128 entries. When the MQ
    subsystem is brought down or the APM Container address space
    is brought down, the entry in the APM control block was not
    cleared causing the block to fill up. Once the threshold of
    128 is reached, AGMQ0034E is issued. The only way to overcome
    the issue is to IPL z/OS or to create a new subsystem.
    

Local fix

Problem summary

  • AGMQ0034E error as the APM control block entries are not
    cleared, even during AGMQ TERM Mxxx.
    

Problem conclusion

  • The Z APM MQ Data collector was updated to clear the entry
    when a AGMQ TERM Mxxx is issued. The proper sequence to
    follow before bringing down MQ or zAPM container proc
    (AGMAPROC) is to issue a AGMQ TERM Mxxx.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA63038

  • Reported component name

    Z APM CONNECT

  • Reported component ID

    5698ABF00

  • Reported release

    610

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-03-28

  • Closed date

    2022-04-12

  • Last modified date

    2022-05-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UJ08194

Modules/Macros

  • AGMPAPI  AGMQAPIX AGMQCOLL AGMQINST AGMQRSMG AGMQSSIN AGMQSTBC
    AGMQSTBX AGMQSTOP AGMQSTRT AGMQXCOM
    

Fix information

  • Fixed component name

    Z APM CONNECT

  • Fixed component ID

    5698ABF00

Applicable component levels

  • R610 PSY UJ08194

       UP22/04/14 P F204

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSCL4Q","label":"IBM Z Application Performance Management Connect"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610"}]

Document Information

Modified date:
04 May 2022