APAR status
Closed as program error.
Error description
Following the successful completion of an IEBCOPY COPYGRP or COPYGROUP with the GENS=ALL parameter the PDSE Generation Data Index records in the target PDSE will have uninitialized member length data. Subsequent STOW RECOVERG or STOW RG (ReplaceGeneration) processing against the target PDSE is likely to fail with an S0C1 ABEND out of the PDSE module IGWDDCR2+70AE at the z/OS 2.5 base level. Associated dump title: COMPID=DF115,CSECT=IGWDDCR2+70AE,DATE=03/22/21,MAINTID=NONE NON,ABND=0C1,RC=00000000,RSN=00000001 Symptom Dump IEA995I SYMPTOM DUMP OUTPUT 553 SYSTEM COMPLETION CODE=0C1 REASON CODE=00000001 TIME=20.59.33 SEQ=16611 CPU=0000 ASID=0035 PSW AT TIME OF ERROR 075C2001 89844EA6 ILC 2 INTC 01 NO ACTIVE MODULE FOUND - PRIMARY NOT EQUAL TO HOME NAME=UNKNOWN DATA AT PSW 09844EA0 - A7840005 00005830 853918F3 AR/GR 0: 00000003/00000000_00000106 1:00000000/00000000_00000040 2: 00000000/00000000_00000000 3:00000000/00000010_00000008 4: 00000000/00000000_00000001 5:00000001/00000000_7E292280 6: 00000002/00000000_7E293490 7:00000000/00000010_02900160 8: 00000000/00000000_7E292C8F 9:00000000/C9C7E6C9_00000014 A: 00000000/00000000_7ED95130 B:00000000/00000000_00000000 C: 00000000/00000000_098469B0 D:00000000/00000000_7E291C90 E: 00000001/00000000_09844BEC F:00000007/00000000_00000008 KNOWN IMPACT: The inability to recover or replace PDSE member generations in the target PDSE of an IEBCOPY COPYGRP or COPYGROUP with the GENS=ALL parameter. VERIFICATION STEPS: Request detailed software EREP for time period of the dump and review for the following Search Argument Abstract: PIDS/5695DF115 RIDS/IGWDDSC0#L RIDS/IGWDDCR2 AB/S00C1 PRCS/00000001 REGS/0E2BA REGS/C1B0A RIDS/IGWDSRCV#R or A dump title match. ADDITIONAL SYMPTOMS: MSGIEC911I 315-00,JOBNAME,STEP02 ,SAM00001,00000024,06105AF8 PDSE/K ABENDC01
Local fix
BYPASS/CIRCUMVENTION: Avoid IEBCOPY generation copy processing. This entitles IEBCOPY COPYGRP or COPYGROUP with the GEN=ALL parameter
Problem summary
**************************************************************** * USERS AFFECTED: * * All PDSE users * **************************************************************** * PROBLEM DESCRIPTION: * * Copying PDSE member generations using IEBCOPY with the * * GENS=ALL option produces generations which can result in an * * intentional 0C1 error when the generation is recovered due * * to an incorrect length being written in the generation * * metadata. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
Corrected the code so new copies will have the correct internal length in the metadata. In addition, any generation created by the previous errant behavior will be tolerated and able to be recovered correctly. KEYWORDS: PDSE/K
Temporary fix
Comments
APAR Information
APAR number
OA62837
Reported component name
EXTENDED DATA S
Reported component ID
5695DF115
Reported release
250
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-02-11
Closed date
2022-03-25
Last modified date
2022-06-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ08085 UJ08086 UJ08087
Modules/Macros
IGWDSCM1 IGWDDCR2
Fix information
Fixed component name
EXTENDED DATA S
Fixed component ID
5695DF115
Applicable component levels
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"250"}]
Document Information
Modified date:
06 July 2022