Error description

  • Writting multi DB2 image copies into multivolume tape
    might lead to overwrite data on tape managed by RMM
    .
    DB2 Image Copy tool opening with INOUT a standard labeled tape
    data set to read it forward but the volume that open has
    positioned the data set to is not the actual first volume of the
    data set may receive following messages:
    
    IEC501A M dev,tapevol2,SL,,jobname,stepname,dsname -
    RACK=tepavol2
    IEC712I dev,tapvol2,jobname,stepname,ddname-nu READ - NOT FIRST
    VOLUME OF DATA SET
    IEC716I nu:TAPE MULTIVOLUME LIST CORRECTED
    IEC502E R dev,tapevol2,SL,jobanme
    *IEC501A M dev,taoevol1,SL,,jobanme,stepname,dsname
    
    In that case, RMM does not reject the mount request permitting
    the dataset to be overwritten from first and seconde volume
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All DFSMSrmm users having option MASTEROVERWRITE(ADD)        *
    * specified in their EDGRMMxx parmlb member and using          *
    * applications writing to tapes with the OPEN mode INOUT, for  *
    * example, DB2 Image Copy tool.                                *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * In the case when an application program opens a tape data    *
    * set with INOUT, but the volume that the open processing has  *
    * positioned the data set to, is not the first volume of the   *
    * data set, then  after mounting the requested volume in       *
    * response to IEC501A:                                         *
    *                                                              *
    * *IEC501A M 0590,A10511,SL,,JOB1,STEPN,                       *
    *   DSN1 - RACK=A10511                                         *
    *                                                              *
    * the following messages get issued unexpectedly:              *
    *                                                              *
    *  IEC712I 0590,A10511,JOB1,STEPN,TAPE                         *
    *   READ - NOT FIRST VOLUME OF DATA SET                        *
    *  IEC716I TAPE    :TAPE MULTIVOLUME                           *
    *   LIST CORRECTED                                             *
    *  IEC502E R 0590,A10511,SL,JOB1,STEPN                         *
    *   - RACK=A10511                                              *
    *                                                              *
    * This is followed then by the subsequent mount requests for   *
    * the volumes from the multivolume list:                       *
    *                                                              *
    * *IEC501A M 0590,A10510,SL,NOCOMP,JOB1,                       *
    *   STEPN,DSN1 - RACK=A10510                                   *
    *  IEC502E K 0590,A10510,SL,JOB1,STEPN,                        *
    *   DSN1 - RACK=A10510                                         *
    * *IEC501A M 0590,A10511,SL,NOCOMP,JOB1,                       *
    *   STEPN,DSN1 - RACK=A10511                                   *
    *                                                              *
    * Provided that the application program actually performs      *
    * writing, this results in the dataset being overwritten on    *
    * the volumes mounted.                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Apply the applicable PTF(s).                                 *
    ****************************************************************
    The program does not provide the correct processing for the case
    described.
    The volume should have been rejected with the message
     EDG4051I VOLUME volser REJECTED. INSTALLATION OPTION PREVENTS
     OVERWRITE OF FILES ON MASTER VOLUMES
    right after mounting it in response to the very first mount
    request.
    

Problem conclusion

  • The problem has been fixed.
    

Temporary fix

  • *********
    * HIPER *
    *********
    
    *********
    
    *********
    The ++APAR is available upon request.
    

Comments

APAR Information

  • APAR number

    OA62816

  • Reported component name

    DFSMSRMM

  • Reported component ID

    5695DF186

  • Reported release

    240

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-02-08

  • Closed date

    2022-04-04

  • Last modified date

    2022-05-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UJ08151 UJ08152 UJ08153

Modules/Macros

  • EDGSOCE
    

Fix information

  • Fixed component name

    DFSMSRMM

  • Fixed component ID

    5695DF186

Applicable component levels

  • R230 PSY UJ08151

       UP22/04/27 P F204 ¢

  • R250 PSY UJ08153

       UP22/04/27 P F204 ¢

  • R240 PSY UJ08152

       UP22/04/27 P F204 ¢

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z\/OS"}],"Version":"240"}]

Document Information

Modified date:
04 May 2022