A fix is available
APAR status
Closed as program error.
Error description
When SYNCIO Read or Write processing has been requested by an application but cannot be used due to a customer correctable reason (ex. zHPF is disabled), the number of such requests are accumulated and reported by Media Manager in the Synchronous I/O Sections 2 and 3 of SMF 42 records (subtypes 5 and 6) while the request is satisfied by MM using non-SYNCIO processingie. asynchronous I/O). However, based on the MM non-SYNCIO processing performed, it is possible that the number of attempted SYNCIO requests (S42SNRDT, S42SNWTT) will not be recorded in Synchronous I/O Section 1 (which is shared between subtype 5 and 6 SMF 42 records). This can result in the Synchronous I/O Section 1 portion of the SMF 42 record to be empty. MMKEYS: MM2021 MMZHL MMSMF42
Local fix
BYPASS/CIRCUMVENTION: None
Problem summary
**************************************************************** * USERS AFFECTED: * * Users of SMF Records Type 42 Subtype 5 and 6 with * * zHyperLink enabled on D/T2107 storage subsystems. * * * * * **************************************************************** * PROBLEM DESCRIPTION: * * SyncIO errors detected by Media Manager are reported in SMF * * Record Type 42, subtype 5 and 6 SyncIO Sections 2 and 3, * * but not SyncIO Section 1. This occurred when a SyncIO error * * was detected by Media Manager and the SyncIO Exit was not * * called. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
The driver layer software now passes information to the device layer indicating a SyncIO error was detected. SyncIO Section 1 now contains the SyncIO Attempts recorded in Section 2 and 3.
Temporary fix
Comments
APAR Information
APAR number
OA62651
Reported component name
DEVICE SUPPORT
Reported component ID
5695DF111
Reported release
230
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-01-05
Closed date
2022-08-03
Last modified date
2022-09-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ08972 UJ08973 UJ08974
Modules/Macros
IECDSTAT
Fix information
Fixed component name
DEVICE SUPPORT
Fixed component ID
5695DF111
Applicable component levels
R250 PSY UJ08974
UP22/08/31 P F208
R240 PSY UJ08973
UP22/08/31 P F208
R230 PSY UJ08972
UP22/08/31 P F208
Fix is available