A fix is available
APAR status
Closed as program error.
Error description
ProcOps ISQSTOP command terrminates in error after LOGOFF timeouts from ISQ-tasks. Re-issue not possible without manual intervention.
Local fix
n/a
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM Z System Automation V4R3 * * or V4R2 using Processor Operations. * **************************************************************** * PROBLEM DESCRIPTION: Shutdown of the Processor Operations * * application may hang because some * * autotasks started by Processor * * Operations could not be stopped * * gracefully. * **************************************************************** During shutdown of Processor Operations all autotasks (ISQnnnnn) are instructed to execute the NCCF LOGOFF command. Due to circumstances outside the control of Processor Operations this might not be successful in all cases. The Processor Operations shutdown will not proceed and there will be leftover autotasks still executing (visible via the TASKUTIL command).
Problem conclusion
The shutdown processing has been enhanced. After having issued the LOGOFF commands to all Processor Operations autotasks possibly leftover autotasks are queried and identified. For these tasks Processor Operations then issues STOP FORCE=<taskname> commands twice to force the autotask to stop. If NetView indicates that the autotask could be stopped in a normal manner a STOP TASK=<taskname> command is issued. The shutdown processing may be delayed up to 3 minutes as the STOP FORCE command needs about one minute to take effect and up to two attempts. The commands are issued in a loop ending when all autotasks have been stopped or three iterations (it. 1 & 2: commands issued, it. 3: final check) have been done. As a result of a STOP FORCE command the corresponding autotask may abend with a system code X"EC4". Changed Modules: ISQSTART, ISQSTOP DOCUMENTATION UPDATE: Changes have been made to IBM Z System Automation 4.2 Messages and Codes (SC34-2719-02) and IBM Z System Automation 4.3 Messages and Codes (SC34-2719-03).
Temporary fix
Comments
APAR Information
APAR number
OA62554
Reported component name
SYSTEM AUTO Z/O
Reported component ID
5698SA300
Reported release
420
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-12-07
Closed date
2022-06-02
Last modified date
2022-09-08
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ08149 UJ08150 UJ08175 UJ08176
Modules/Macros
DSIISQ09 ISQ09 ISQASTP ISQE ISQJ
| SC34271902 | SC34271903 |
Fix information
Fixed component name
SYSTEM AUTO Z/O
Fixed component ID
5698SA300
Applicable component levels
R420 PSY UJ08150
UP22/06/08 P F206
R421 PSY UJ08176
UP22/06/08 P F206
R430 PSY UJ08149
UP22/06/08 P F206
R431 PSY UJ08175
UP22/06/08 P F206
Fix is available