Error description
1 - zAPM Connect DB2 SQL call causes a User Error in IMS application 2 - IMS Connect transaction is not reported on the User Interface (UI) when a lower case clientid is entered.
Local fix
n/a
Problem summary
**************************************************************** * USERS AFFECTED: All Z APM Connect v6.1.0 users. * **************************************************************** * PROBLEM DESCRIPTION: 1 - zAPM Connect DB2 SQL call routine * * is passing back to caller an invalid * * return code in some instances, which * * can cause a User Error message to be * * reported. * * * * 2 - IMS Connect clientid in lower * * case causes a mismatch between IMS * * Connect and IMS in the Horizontal * * links. * **************************************************************** * RECOMMENDATION: Apply this PTF. * **************************************************************** 1 - DB2 DB exit passes back invalid return code in some instances. 2 - IMS Connect clientid in lower case causes a mismatch between IMS Connect and IMS zAPM Horizontal link events causing transactions not to be reported on the UI.
Problem conclusion
1 - DB2 exit always passes back IMS database call return code from application. 2 - Clientid is converted to upper case in zAPM Connect like is done in IMS Connect.
Temporary fix
Comments
APAR Information
APAR number
OA62240
Reported component name
Z APM CONNECT
Reported component ID
5698ABF00
Reported release
610
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-10-07
Closed date
2022-03-31
Last modified date
2022-10-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ07179
Modules/Macros
AGMDB20E AGMDB20F AGMDBF0E AGMDBF0F AGMDLA0E AGMDLA0F AGMTEC0E AGMTEC0F
Fix information
Fixed component name
Z APM CONNECT
Fixed component ID
5698ABF00
Applicable component levels
R610 PSY UJ09066
UP22/09/14 P F209
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.