Error description

  • Noticed STATUS(SUSPENDED) message after issuing INGHWCMD cpcname
    STATCOM command.
    
    This was caused by an unauthorized Cglobal
    ING.0SUSPEND.RADNWIBM.RADZ15 with a value of RADNWIBM.RADZ15
    being injected by SAz/OS.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IBM Z System Automation V4R2    *
    *                 or V4R1 using the hardware automation        *
    *                 functions of the product or are using GDPS   *
    *                 to monitor and control IBM Z.                *
    ****************************************************************
    * PROBLEM DESCRIPTION: While using the hardware automation     *
    *                      function or GDPS it could happen that   *
    *                      - the session suspend state is not      *
    *                        cleared from persistent storage       *
    *                      - the SA-BCPii instead of the ProcOps   *
    *                        suspend state is changed              *
    ****************************************************************
    Resuming a suspended connection for a processor (target
    hardware) could lead to an improper suspend state in the
    persistent storage which causes that the connection is
    suspended again after a NetView recycle. This could happen when
    during the resume operation a timeout occurs or the associated
    WAIT is canceled by using the GO command.
    When suspending an ISQET32 ProcOps session it could happen
    that the SA-BCPii (INTERNAL connection) instead of the ProOps
    suspend state is changed.
    

Problem conclusion

  • The resume operation is changed and the suspend state will
    always be cleared from persistent storage. This reflects the
    intend that the session should be resumed. After a NetView
    recycle the policy settings will be applied as specified.
    When suspending an ISQET32 ProcOps session the corresponding
    ProcOps suspend state will be changed. Additional checking
    ensures that no SA-BCPii session state will be affected.
    
    Changed Modules: INGCHW00, INGRX810
    
    FixCat Keyword: GDPS/K
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA62235

  • Reported component name

    SYSTEM AUTO Z/O

  • Reported component ID

    5698SA300

  • Reported release

    420

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-10-06

  • Closed date

    2022-01-19

  • Last modified date

    2022-02-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UJ07578 UJ07579

Modules/Macros

  • INGCHW00 INGHW0VN INGRX810
    

Fix information

  • Fixed component name

    SYSTEM AUTO Z/O

  • Fixed component ID

    5698SA300

Applicable component levels

  • R410 PSY UJ07579

       UP22/01/21 P F201

  • R420 PSY UJ07578

       UP22/01/21 P F201

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSWRCJ","label":"Tivoli System Automation for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"420"}]

Document Information

Modified date:
02 February 2022