IBM Support

OA62199: ABEND 0C8 PIC8 FIXED-POINT OVERFLOW EXCEPTION IN HASCPHAM

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • ABEND 0C8 PIC8 observed in HASCPHAM. No other messages are
    present. ABEND may be observed only in SYSTRACE.
    
    ANALYSIS:
    ABEND 0C8 PIC8 observed in HASCPHAM. In this case, issue occurrs
    at HASCPHAM+314 as part of HPMOVE PUT SUBROUTINE. Job task is
    producing large amounts of output to a particular SYSPRINT DD.
    JCTXOUT field is used to count number of records. At time of the
    error, JCTXOUT is maxed at x'7FFFFFFF'. Caller of this code has
    set bit PSWPFPO in the PSW which means that fixed point
    overflows are not allowed. Thus, instead of overflowing, ABEND
    0C8 PIC8 occurs.
    
    VERIFICATION STEPS:
    1. ABEND 0C8 in HASCPHAM PUT routine
    2. JCTXOUT field id maxed 7FFFFFFF
    3. PSW indicates PSWPFPO is on, disallowing fixed-point
    overflows
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All users of HJE77B0, HJE77C0, and                           *
    * HJE77D0.                                                     *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * ABENDS0C8-RC08 may occur in HASCPHAM                         *
    * module when job produces large amount                        *
    * of output with PSWPFPO set on.                               *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    With PSW (Program Status Word) PSWPFPO (Fixed point overflow
    mask) bit set on by the SSI caller, a job that produces more
    than 2,147,483,647 records may cause an overflow and raise
    ABEND0C8-RC08 when the HASCPHAM module attempts to increment
    the JCTXOUT (Generated Output Records) field.
    

Problem conclusion

  • TYPE/RESTART (WARM) IPL/REQUIRED (YES) CLPA (YES)
    
    CLPA is needed only if HASCxxxx modules currently reside in
    the pageable link pack area (PLPA).
    
    The HASCLINK and HASCPHAM modules were changed to clear the
    PSW program mask before every call to JES2 services and
    restore the mask upon return.
    
    APAR OA62199 prereq's (and sup's) for FMID HJE77B0:
    Pre's: * NONE *
    
    APAR OA62199 prereq's (and sup's) for FMID HJE77C0:
    Pre's: * NONE *
    
    APAR OA62199 prereq's (and sup's) for FMID HJE77D0:
    Pre's: * NONE *
    

Temporary fix

Comments

  • ×**** PE22/07/01 FIX IN ERROR. SEE APAR OA63479  FOR DESCRIPTION
    

APAR Information

  • APAR number

    OA62199

  • Reported component name

    JES2

  • Reported component ID

    5752SC1BH

  • Reported release

    7B0

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-09-30

  • Closed date

    2022-06-03

  • Last modified date

    2022-09-08

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UJ08595 UJ08596 UJ08597

Modules/Macros

  • HASCPHAM HASCLINK
    

Fix information

  • Fixed component name

    JES2

  • Fixed component ID

    5752SC1BH

Applicable component levels

  • R7D0 PSY UJ08597

       UP22/06/15 P F206

  • R7B0 PSY UJ08595

       UP22/06/15 P F206

  • R7C0 PSY UJ08596

       UP22/06/15 P F206

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"7B0"}]