Error description
DUMP TITLE=JES2 SUBSYS=JES2 z/OS 2.3 MOD=HASJES20 CODE =$DIS DISASTROUS ERROR AT LABEL $BVORPHN $HASP088 JES2 ABEND ANALYSIS 936 $HASP088 ------------------------------------------------------ $HASP088 FMID = HJE77B0 LOAD MODULE = HASJES20 $HASP088 SUBSYS = JES2 z/OS 2.3 $HASP088 DATE = 2021.nnn TIME = nn.nn.nn $HASP088 DESC = DISASTROUS ERROR AT LABEL $BVORPHN $HASP088 MODULE MODULE OFFSET SERVICE ROUTINE EXIT $HASP088 NAME BASE + OF CALL LEVEL CALLED ## $HASP088 -------- -------- ------- ------- ---------- ---- $HASP088 HASPRAS 00040D28 + 0005EA NONE *ERROR $DIS $HASP088 HASPCKPT 2E600000 + 00DDEE OAnnnnn $DISTERR $HASP088 HASPIRDA 2E7D6C60 + 00424C OAnnnnn $BERTFIX $HASP088 HASPIRA 2E7D1000 + 000634 OAnnnnn IRDA $HASP088 PCE = INIT (2E7D2438) ANALYSIS: During a warm start JES2 experienced CKPT damage and corrected the damage after issuing HASP486 and HASP483 messages. Then, when a second system was warm started in the MAS, it encountered a $DIS error at label $BVORPHN. The problem is a JOE placed on the FREE queue during the queue rebuild had a BERT associated with it that were not considered by the HASPJOS routine $#RBDCHK which resulted in the BERT being orhpaned. KNOWN IMPACT: JES2 may ABEND and issue message HASP483 prompting for a queue rebuild. JES2 will recover successfully after the ABEND and rebuild. VERIFICATION STEPS: 1. JES2 member warm starts and detects JES2 CKPT is damaged. 2. Job queue rebuild is performed and completes successfully (HASP440) 3. On a subsequent warm start, a $DIS error occurs at label $BVORPHN for an orphaned BERT that was associated with a JOE previously placed on the FREE queue.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of HJE77B0, HJE77C0, and * * HJE77D0. * **************************************************************** * PROBLEM DESCRIPTION: $DIS DISASTROUS ERROR AT LABEL * * $BVORPHN may occur on the next warm * * start after a job queue rebuild * * ($HASP440). * **************************************************************** * RECOMMENDATION: * **************************************************************** During a warm start, in checkpoint validation, a damaged Job Output Element (JOE) may be found and moved to the free queue. If the JOE has a BERT associated with it, the BERT is orphaned. On the next warm start, the orphaned BERT is detected and a $DIS DISASTROUS ERROR AT LABEL $BVORPHN ABEND is issued.
Problem conclusion
TYPE/RESTART (HOT) IPL/REQUIRED (NO) CLPA (NO) Code in module HASPJOS was modified to free any BERTs associated with a JOE before moving the JOE to the free queue. Code in module HASPIRDA was modified for a warm start to check for BERT problems after fixing any problem found in the job queue or Job Output Table (JOT). Searchable keywords: - $HASP440 - msgHASP440 APAR OA62057 prereq's (and sup's) for FMID HJE77B0: Pre's: * NONE * APAR OA62057 prereq's (and sup's) for FMID HJE77C0: Pre's: * NONE * APAR OA62057 prereq's (and sup's) for FMID HJE77D0: Pre's: * NONE *
Temporary fix
Comments
APAR Information
APAR number
OA62057
Reported component name
JES2
Reported component ID
5752SC1BH
Reported release
7B0
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-08-30
Closed date
2022-11-21
Last modified date
2023-01-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ09657 UJ09658 UJ09659
Modules/Macros
HASPIRDA HASPJOS
Fix information
Fixed component name
JES2
Fixed component ID
5752SC1BH
Applicable component levels
R7B0 PSY UJ09659
UP22/12/07 P F212
R7C0 PSY UJ09658
UP22/12/07 P F212
R7D0 PSY UJ09657
UP22/12/07 P F212