A fix is available
APAR status
Closed as program error.
Error description
An abend (code 0C4/AKEA) occurred when attempting to initialize the Z APM CICS agent in a z/OS 2.4 environment.
Local fix
Problem summary
At startup, the Z APM CICS monitoring agent used offsets in control blocks to verify Z APM install DDs. z/OS 2.4 introduces different offsets within task I/O tables, causing the CICS agent to access incorrect storage.
Problem conclusion
The Z APM CICS monitoring agent was updated to use a z/OS-supported MVS service to check for DD names.
Temporary fix
Comments
APAR Information
APAR number
OA62040
Reported component name
Z APM CONNECT
Reported component ID
5698ABF00
Reported release
610
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-08-27
Closed date
2021-09-14
Last modified date
2021-10-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ06639
Modules/Macros
AGMPAPI AGMPINIT AGMQAPID
Fix information
Fixed component name
Z APM CONNECT
Fixed component ID
5698ABF00
Applicable component levels
R610 PSY UJ06639
UP21/09/28 P F109