A fix is available
APAR status
Closed as program error.
Error description
IRRUT200 RENAMEACTIVATE suffers and ABEND0C4 after receiving an expected ABENDD37 in IEBGENER because the output file is too small. Recovery needs to process without triggering the second ABEND.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Invokers of IRRUT200 * **************************************************************** * PROBLEM DESCRIPTION: * * IRRUT200 does not recover correctly if IEBGENER fails with * * an ABEND. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
IRRUT200 recovery has been updated to correctly recover from failures in the copy routine. The IRRUTSUB rename routine has been updated to initialize all parms correctly. IDCAMS REPRO now is used for all database copying. The Security Server RACF System Programmer's Guide (SA23-2287-50) regarding IRRUT200 has been updated. References to IEBGENER (and ICEGENER) are removed. The Security Server RACF Messages and Codes book (SA23-2291-50) has been updated. Messages IRR62065I and IRR62066I are removed.
Temporary fix
Comments
APAR Information
APAR number
OA61995
Reported component name
RACF
Reported component ID
5752XXH00
Reported release
7D0
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-08-18
Closed date
2021-09-09
Last modified date
2021-12-08
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ06610
Modules/Macros
IRRUTSUB IRRUT200
| SA23228750 | SA23229150 |
Fix information
Fixed component name
RACF
Fixed component ID
5752XXH00
Applicable component levels
R7D0 PSY UJ06610
UP21/09/29 P F109
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z\/OS"}],"Version":"7D0"}]
Document Information
Modified date:
09 December 2021