Error description
User defines an application from the main menu as Foreground. Upon login to CLSS, they are directed to this applcation without stopping at the main menu panel KLSVSEL1. The user has a trigger set for dialog KLSGOTO to jump to other applications. When they enter \g n (the menu number for an appliation) it fails with message - CG907 Unable to start session "n" However, if they use the goto triger with a session name CLSS is able to start the session - i.e. \g name
Local fix
Use the session name rather than the session number
Problem summary
**************************************************************** * USERS AFFECTED: Users of IBM CL/SuperSession 210 * **************************************************************** * PROBLEM DESCRIPTION: KLSGOTO INCORROUT with KLSOPTBN and * * initial foreground session * **************************************************************** * RECOMMENDATION: Apply the PTF * **************************************************************** When KLSOPTBN is enabled and a session is defined with an initial status of foreground, the \g trigger (KLSGOTO) fails.
Problem conclusion
When the user's session table is not available, and alternate table is used.
Temporary fix
Comments
APAR Information
APAR number
OA61696
Reported component name
CL/SUPERSESSION
Reported component ID
5601B2800
Reported release
210
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-07-08
Closed date
2021-08-02
Last modified date
2021-09-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ06222 OA61896
Modules/Macros
KLSGOTO
Fix information
Fixed component name
CL/SUPERSESSION
Fixed component ID
5601B2800
Applicable component levels
R210 PSY UJ06222
UP21/08/03 P F108
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z\/OS"}],"Version":"210"}]
Document Information
Modified date:
02 September 2021