Error description

  • An ABEND878 can occur due to ELSQA sp249 storage shortage when
    an initiator address space sees a build up of CIST control
    blocks over time.  The CIST is a table associated to the SHOWCAT
    and SHOWCB macros.
    
    |  CIST.. .......}.  |
    |  .........dsname.  |
    
    In Initiator address spaces which persist, these CIST control
    blocks will remain orphaned instead while new CIST blocks are
    acquired anew.   Over time if the Initiatior is not restarted or
    drained, this accumulation can lead to an abend878
    
    
    ADDITIONAL SYMPTOMS:
    CATKEYS: CAT2021 CATABEND
    

Local fix

  • BYPASS/CIRCUMVENTION:
    VSM CHECKREGIONLOSS in DIAGxx can be used to automatically
    releive storage issues in the Initiator by setting a threshold
    and automatically recycling the initiator when storage begins to
    creep.  VSM CHECKREGIONLOSS(256K,10M) is a default and can be
    increased by 10M if found it is recycling too often
    
    RECOVERY ACTION:
    Drain initiators if abend878s are actively occurring
    
    WLM Managed
    $P XEQ
    P INIT,A=     (D A,INIT to find init#)
    $S XEQ        (once initiator fully inactive in SDSF)
    
    JES2 Managed
    $PInn         (where nn is init #)
    $SInn
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * HDZ220 and up users who use VSAM Control                     *
    * Interval (CI) RBAs to address records                        *
    * instead of the ds name, or those who use                     *
    * vendor program IAM.                                          *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See Error Description                                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • The Catalog component has been updated to ensure that these
    control blocks are freed at the end of the step.
    

Temporary fix

  • *********
    * HIPER *
    *********
    APPLY ++APAR AND PROVIDE FEEDBACK.
    

Comments

APAR Information

  • APAR number

    OA61323

  • Reported component name

    ICF CATALOG & I

  • Reported component ID

    5695DF105

  • Reported release

    230

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-04-26

  • Closed date

    2021-11-12

  • Last modified date

    2022-03-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UJ07117 UJ07118 UJ07119 UJ07120

Modules/Macros

  • IGG0CLH1
    

Fix information

  • Fixed component name

    ICF CATALOG & I

  • Fixed component ID

    5695DF105

Applicable component levels

  • R250 PSY UJ07119

       UP21/12/08 P F112 ¢

  • R240 PSY UJ07118

       UP21/12/08 P F112 ¢

  • R230 PSY UJ07117

       UP21/12/08 P F112 ¢

  • R220 PSY UJ07120

       UP21/12/09 P F112 ¢

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.