A fix is available
APAR status
Closed as program error.
Error description
ABEND 0C4 or 0D5 in CKFCOLL (CKFNT) can occur when address space information could not be collected. For example: Abend PSW 470D4000 80163ADC 00060011 7F74C801 (AMODE 31 AR mode problem state key 0) system abend 0C4-11 (invalid storage address - page) Data around PSW: <0042B2790200|D247D0B04000> or Abend PSW 070D4000 8008200C 00060011 7F816801 (AMODE 31 AR mode problem state key 0) system abend 0D5-04001300 (address space not swapped in) Data around PSW: <0042B2790200|D247D0B04000> Neither abend should occur. When an address space being collected is terminating, message CKF0592 should be issued reporting 0C4 instead of CKFCOLL terminating with ABEND 0C4. When an address space being collected is swapped out, no error should be reported.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: All users of zSecure Collect. * **************************************************************** * PROBLEM DESCRIPTION: zSecure Collect might ABEND0C4, * * ABEND0D5, or ABEND0E0 while collecting * * application name/token pairs * * information. * **************************************************************** * RECOMMENDATION: Apply the PTF provided. * **************************************************************** When zSecure Collect processes program's name/token pairs information for processes that are being terminated or swapped-out, it might ABEND0C4, ABEND0D5, or ABEND0E0.
Problem conclusion
zSecure Collect has been modified so that it issues a MSGCKF0592 instead of ABEND0C4, ABEND0D5, or ABEND0E0 while collecting program's name/token pairs information for processes that are being terminated or swapped-out.
Temporary fix
Comments
APAR Information
APAR number
OA61205
Reported component name
ZSEC BASE,ADMIN
Reported component ID
5655T0100
Reported release
240
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-04-13
Closed date
2021-06-03
Last modified date
2021-07-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
OA61524 UJ05678
Modules/Macros
CKACICS CKACMEM CKAFMTA CKAINEA CKAINPH CKAOUAS CKAOUIS CKAOUMEM CKAOUNIX CKAOUSH CKAOUSOP CKAOUSVC CKAOUXIT CKARNAF CKARPROG CKASFW CKASINT CKASMF77 CKASMFI CKASMRT CKFACF2 CKFALLOC CKFASYS CKFAXCP CKFAXVM CKFCATA CKFCATV CKFCICS CKFCMON CKFCOLL CKFDB2 CKFDSN CKFDSNA CKFFILE CKFHSM CKFICSF CKFIMS CKFINIT CKFINPUT CKFJES2 CKFJES3 CKFJFC2 CKFJFCB CKFLMOD CKFMAIN CKFNT CKFPC CKFPDS CKFPDSE CKFRACF CKFRMF CKFRPROG CKFSCAN CKFSMF CKFSMS CKFSSCT CKFUCBV CKFUCM CKFUNIX CKFUTF CKFVSMK CKFVTAM CKFVVDS CKFWMQ CKGCPIC CKGIFMT CKGINIT CKGINP CKGINPC CKGINPI CKGINPU CKGLCMD CKGLIST CKGPWDC CKGRACF CKGTSOP CKGUSRD CKNATLS CKNCLNR CKNCOMM CKNCOMR CKNDPLX CKNFMT CKNINP@ CKNRACI CKNRQAL CKNRQDO CKNRQRF CKNSERVE CKNSVPC CKRACIN CKRACTS CKRADSN CKRALLOC CKRCARL@ CKRCFS CKRCFV CKRCINI2 CKRCKFIN CKRCKGF CKRDBGS CKRDDAT CKRDT CKRDUNL CKRENQ CKRFMT CKRGEVL CKRINFC CKRINLS CKRINP@ CKRINPA CKRINPC CKRINPI CKRINPL CKRINPM CKRINPN CKRINPO CKRINPS CKRINPUT CKRLIST CKRMAIN CKRMODF CKRNCVA CKROPEN CKROUACC CKROUICB CKROUOPT CKROUPUT CKROURPT CKROUTKN CKROUXL CKRPDSE CKRPRTR CKRQUAL CKRSELIN CKRSMMO CKRSMRY CKRSYDB CKRTSO CKRUTF CKRVCPQ CKXTSO GKRACIN GKRACTS GKRADSN GKRALLOC GKRCARL@ GKRCFS GKRCFV GKRCICS GKRCINI2 GKRCKFIN GKRCKGF GKRCMEM GKRDBGS GKRDDAT GKRDT GKRDUNL GKRENQ GKRFMT GKRFMTA GKRGEVL GKRINEA GKRINFC GKRINLS GKRINP@ GKRINPA GKRINPC GKRINPH GKRINPI GKRINPL GKRINPM GKRINPN GKRINPO GKRINPS GKRINPUT GKRLIST GKRMAIN GKRMODF GKRNCVA GKROPEN GKROUACC GKROUAS GKROUICB GKROUIS GKROUMEM GKROUNIX GKROUOPT GKROUPUT GKROURPT GKROUSH GKROUSOP GKROUSVC GKROUTKN GKROUXIT GKROUXL GKRPDSE GKRPRTR GKRQUAL GKRRNAF GKRRPROG GKRSELIN GKRSFW GKRSINT GKRSMF77 GKRSMFI GKRSMMO GKRSMRT GKRSMRY GKRSYDB GKRTSO GKRUTF GKRVCPQ
Fix information
Fixed component name
ZSEC BASE,ADMIN
Fixed component ID
5655T0100
Applicable component levels
R240 PSY UJ05678
UP21/06/04 P F106
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Type":"MASTER","Line of Business":{"code":"LOB24","label":"Security Software"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSPQTM","label":"IBM Security zSecure Admin"},"Version":"All Versions"}]
Document Information
Modified date: