IBM Support

OA61006: GDPS HARDWARE FUNCTION FAILS TO START, NO LOCAL CPC FOUND. ING828I GDPS CURRENTLY CANNOT USE THE LOCAL SE CONNECTION

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • GDPS hardware function fails to start, no LOCAL CPC found.
    BCPII not connected - message ING828I received;
    message ING825I not received.
    ING828I GDPS CURRENTLY CANNOT USE THE LOCAL SE CONNECTION
    also see
    GTP4     AOFA0099 STATCOM CEC4 STATUS(NOT_CONNECTED)
             CPCSNAME(IBM390PS.GR15CEC4) DEST() LASTS()
             TSTIME(210303173424)
    GDPS/K
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IBM Z System Automation V4R2 or *
    *                 V4R1 using the hardware automation functions *
    *                 of the product to monitor and control IBM Z. *
    *                 All GDPS users using System Automation V4R2  *
    *                 or V4R1 to monitor and control IBM Z.        *
    *                                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: At System Automation start or           *
    *                      configuration refresh time, in case     *
    *                      processor connections of type INTERNAL  *
    *                      are defined, the local CPC support      *
    *                      element connection is evaluated and     *
    *                      tested.                                 *
    *                                                              *
    *                      The local processor connection detect   *
    *                      logic incorrectly may return CPCnames   *
    *                      as local, which are not requested to be *
    *                      veryfied for local connectivity.        *
    *                      In GDPS environments, message ING828I   *
    *                      is issued for the wrong reason and GDPS *
    *                      does not start its SA-BCPii usage.      *
    ****************************************************************
    Message ING828I is incorrectly issued because of a wrong
    local CPC detection returning incorrect CPCname as the local.
    

Problem conclusion

  • - ReXX macro AOFC0172 was changed. The wrong checking
      was corrected to return only the CPCnames as local
      if that is true and its the CPCname to be checked.
    
    - The following ReXX modules have been rebuild in order to
      pick up the changed AOFC0172 macro:
      INGRX806, INGRX810, INGRX815, and INGRX830.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA61006

  • Reported component name

    SYSTEM AUTO Z/O

  • Reported component ID

    5698SA300

  • Reported release

    420

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-03-04

  • Closed date

    2021-03-15

  • Last modified date

    2021-04-26

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UJ05056 UJ05057

Modules/Macros

  • INGRX806 INGRX809 INGRX810 INGRX815 INGRX830
    

Fix information

  • Fixed component name

    SYSTEM AUTO Z/O

  • Fixed component ID

    5698SA300

Applicable component levels

  • R410 PSY UJ05057

       UP21/03/17 P F103 ¢

  • R420 PSY UJ05056

       UP21/03/17 P F103 ¢

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSWRCJ","label":"IBM Tivoli System Automation for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"420"}]

Document Information

Modified date:
27 April 2021