IBM Support

OA60226: XRC ANTX5119E RC=1017 REAS=0000 FOLLOWING FLASHCOPY WITH RPFC FOR XRC

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • During a FlashCopy Establish of volumes mirrored by XRC, using
    the Remote Pair FlashCopy for XRC feature (RPFC for XRC),
    clients can encounter the following message which causes an XRC
    suspend:
    
    ANTX5119E XRC SESSION(session_id) ENCOUNTERED AN ERROR
    PROCESSING STORAGE CONTROL #### SESSION ##, RC=1017 REAS=0000
    SRVC=0106
    
    VERIFICATION STEPS:
    1. Confirm the existance of the ANTX5119E RC=1017 REAS=0000
    within the SDM LPAR SYSLOG.
    2. Confirm how long these sessions
    have been active without an XEND, and if any volume pairs have
    been
    deleted (XDELPAIR) from the session(s) receiving the error since
    the last XEND.
    3.
    Confirm FlashCopy is executed on XRC Primary volumes.
    

Local fix

  • BYPASS/CIRCUMVENTION:
    An XEND of the XRC sessions is required to clear this condition.
    
    RECOVERY ACTION:
    1. A normal Resync to the XRC sessions will recover the mirror
    temporarily until the next FlashCopy.
    2. An XEND of the sessions
    encountering the RC=1017 will temporarily resolve the issue
    until volume pairs are removed (XDELPAIR) from the session.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * XRC users who exploit Remote Pair FlashCopy (RPFC) in XRC    *
    * sessions which have previously had volumes deleted using     *
    * XDELPAIR.                                                    *
    *                                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * After executing a FlashCopy in the application site, XRC     *
    * suspends with ANTX5119E RC=1017 REAS=0000.                   *
    *                                                              *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • The problem has been corrected.
     KEYWORDS: XRC/K
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA60226

  • Reported component name

    SYSTEM DATA MOV

  • Reported component ID

    5695DF117

  • Reported release

    220

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-09-28

  • Closed date

    2021-03-15

  • Last modified date

    2021-05-07

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UJ05079 UJ05080

Modules/Macros

  • ANTXRSSE
    

Fix information

  • Fixed component name

    SYSTEM DATA MOV

  • Fixed component ID

    5695DF117

Applicable component levels

  • R230 PSY UJ05079

       UP21/03/31 P F103

  • R240 PSY UJ05080

       UP21/03/31 P F103

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z\/OS"}],"Version":"220"}]

Document Information

Modified date:
08 May 2021