IBM Support

OA60162: POSSIBLE PROCOPS AUTO REPLY ERRORS, ISQXCON HMC ISSUE, INGHWSRV COMMAND CONFLICTS

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • 1) z/OS IPL NIP automatic responses may contain duplicated text
    2) ISQXCON or internal functions may fail for HMC connections
    3) INTERNAL connection service command INGHWSRV erroneously
       accepts ProcOps entitiy names
    

Local fix

  • n/a
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IBM Z System Automation V4R2    *
    *                 using the hardware automation functions of   *
    *                 the product to monitor and control IBM Z.    *
    *                 All GDPS users using System Automation V4R2  *
    *                 to monitor and control IBM Z.                *
    ****************************************************************
    * PROBLEM DESCRIPTION: Service command INGHWSRV accepts and    *
    *                      starts execution of commands targeting  *
    *                      processors defined for ProcOps SNMP     *
    *                      use. This can cause extensive error     *
    *                      messages.                               *
    *                                                              *
    *                      The ProcOps IPL/NIP message automation  *
    *                      tries to respond to some operator       *
    *                      prompt messages twice in a row, which   *
    *                      is not correct.                         *
    ****************************************************************
    Extensive error messages with INGHWSRV in case ProcOps defined
    processors are targeted. IPL/NIP prompt messages are answered
    twice by the automation routines.
    

Problem conclusion

  • - Command INGHWSRV/INGRX815 was changed to only issue
      message AOF201I about the wrong target parameter.
    
    - The following ReXX message automation clists have been
      changed to not respond twice to the issued reply:
      ISQRM886, ISQRM888, and ISQRM889.
    
    - Clist INGRX810 was recompiled to correct a wrong
      work item association. No code change.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA60162

  • Reported component name

    SYSTEM AUTO Z/O

  • Reported component ID

    5698SA300

  • Reported release

    420

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-09-06

  • Closed date

    2021-03-03

  • Last modified date

    2021-04-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UJ04965

Modules/Macros

  • INGRX810 INGRX815 ISQRM886 ISQRM888 ISQRM889
    

Fix information

  • Fixed component name

    SYSTEM AUTO Z/O

  • Fixed component ID

    5698SA300

Applicable component levels

  • R420 PSY UJ04965

       UP21/03/04 P F103

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSWRCJ","label":"IBM Tivoli System Automation for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"420"}]

Document Information

Modified date:
02 April 2021