Error description

  • NEW FUNCTION
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Users of HBB77B0 and above on a z16                          *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * New function: Timer supervisor and Hardware Instrumentation  *
    * Services (HIS) exploitation for z16                          *
    * E3931/K                                                      *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    New function: Timer supervisor and Hardware Instrumentation
    Services (HIS) exploitation for z16
    E3931/K
    

Problem conclusion

Temporary fix

Comments

  • New function: Timer supervisor and Hardware Instrumentation
    Services (HIS) exploitation for z16
     E3931/K
    
    Documentation Information:
    z/OS V2R5 & V2R4
    MVS System Commands (SA38-0666-xx)
    - MVS system commands reference
    - - DISPLAY command
    - - - Displaying the timer synchronization mode and ETR ports
          (ETR)
    
    Add new bullet to the list of bullets under "The DISPLAY ETR
    command issues the following information when the sysplex is
    running in STP mode:"
    
    - ETS (external time source) information including ETS ID, ETS
      timing precision, and the PTP Grandmaster ID if the ETS is
      using PTP
    
    MVS System Messages, Vol 6 (GOS-IEA) (SA38-0673-xx)
    - IEA messages
    - - IEA386I
    
    hh.mm.ss TIMING STATUS
    SYNCHRONIZATION MODE = mode
    THIS SERVER IS A STRATUM n
    CTN ID = ctnid [ETS ID = etsid (englishets)]
    ETS Timing Precision = p
    THE STRATUM 1 NODE ID = cpcid
    NUMBER OF TIMING LINKS = ll
    optional text
    
    In the message text:
    ...
    etsid and englishets
    External Time Source (ETS) ID. STP timing mode can have the
    following ETS:
    * CNTP - NTP (Network Timing Protocol) without PPS (Pulse Per
             Second)
    * CNTX - NTP without PPS via secondary
    * PPSN - NTP with PPS
    * PPSX - NTP with PPS via secondary
    * CPTP - PTP (Precision Time Protocol) without PPS
    * CPTX - PTP without PPS via secondary
    * PPPS - PTP with PPS
    * PPPX - PTP with PPS via secondary
    * CMAN - Console manually set time
    * PRTF - PRT Update Failure
    * UNIN - Uninitialized. PRT not set
    * MRGE - Merging with another Stratum 1
    * DNTP - Direct attachment using NTP
    * DPTP - Direct attachment using PTP
    * zzzz - ETS ID is not valid
    * **** - The ETS ID was unavailable at the time of the command
    
    p - ETS level of timing precision.
    * 1 = lowest level of ETS timing precision. IBM highly
          recommends to change to a higher level of ETS timing
          precision like NTP or PTP
    * 2 = This level of ETS timing precision is acceptable, but it
          does not take advantage of the PPS (Pulse Per Second)
          signal to achieve an even higher level of timing
          precision. Financial and banking institutions are
          recommended to change to a higher level of timing
          precision
    * 3 = current highest level of ETS timing precision. This level
          utilizes the PPS (Pulse Per Second) signal
    * U = the ETS has an unknown level of timing precision
    ...
    
    optional text
    One or more of the following lines are issued:
    ...
    
    If one of the three server type lines was issued, then one (or
    two) of these lines might be issued.
    [THIS STP NETWORK HAS NO BACKUP TIME SERVER]
    [THIS STP NETWORK HAS NO SERVER TO ACT AS ARBITER]
    
    This optional line is only issued on a Primary S1 or Alternate
    S1.
    [THERE IS ONLY ONE LINK BETWEEN THE PREFERRED AND BACKUP TIME
    SERVER]
    
    If the ETS is one of the PTP ETS IDs, then the following
    optional line will be issued:
    [PTP Grandmaster ID = xxxxxx.xxxx.xxxxxx]
    where xxxxxx.xxxx.xxxxxx is a unique clock identifier for the
      PTP Grandmaster ID. It is constructed from the clock device's
      MAC address, and it is also displayed on the STP panels on
      the SE/HMC.
    

APAR Information

  • APAR number

    OA60036

  • Reported component name

    SUPERVISOR CONT

  • Reported component ID

    5752SC1C5

  • Reported release

    7C0

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / New Function / CST /

  •  

    Xsystem

  • Submitted date

    2020-08-10

  • Closed date

    2022-05-05

  • Last modified date

    2022-06-08

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UJ08369 UJ08370 UJ08371 UJ08372 UJ08373

Modules/Macros

  • IEAVMPWQ IEAWUQP  IEAVS981 IEAVEWDI IEAVEDSR IEAVSCHA IEAVSCHD
    HISSCORE IHALCCX  IEAVEMIN IHASVTX  IHAHR981 IEAVEJST IEATDISP
    IHASCWA  IEAVEPCO HISYSMPX IHAASCB  IEAVESVC IHASVT   HISPCTR
    IEALCCAP IHALCCA  IEAVWUQA IEAVELCR IFAWICLN IEAVELKX IEAVEINT
    HISICLAS IEAVEAC0 IEAVELK  IEAVEMRQ IEAASCBP IEAVESVT HISYCTRS
    IEAHFXSV IEAVEAT0 IEAVLKRM IEAVESC0 HISPSMF  IEATIMJP IEAVSVCM
    IEAVWUQD IEATTAMR IEAVERMF HISIRTRM IEAVNP21 IEAVEGR  HISSSERV
    IEALCCXP IEASVTP  IEAVEEXT HISNTIMR IEAVEDS0 HISSSGNI IEAVSVTX
    IFAWIPCT IEAVERI  IEAVINIT IEATIMEN IEASVTXP HISSSGNR IEAVWEBI
    IEAVTACR IEAVECPX IEAVCBLS
    

Publications Referenced
SA38066600SA38067300   

Fix information

  • Fixed component name

    SUPERVISOR CONT

  • Fixed component ID

    5752SC1C5

Applicable component levels

  • R7CJ PSY UJ08372

       UP22/05/31 P F205

  • R7DJ PSY UJ08373

       UP22/05/31 P F205

  • R7D0 PSY UJ08371

       UP22/05/31 P F205

  • R7B0 PSY UJ08369

       UP22/05/31 P F205

  • R7C0 PSY UJ08370

       UP22/05/31 P F205

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z\/OS"}],"Version":"7C0"}]

Document Information

Modified date: