A fix is available
APAR status
Closed as new function.
Error description
new function
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: RMF users * **************************************************************** * PROBLEM DESCRIPTION: RMF support for Cryptographic * * Express8S Hardware Security Module on * * the IBM z16 server (E3931/K). * **************************************************************** With this APAR, RMF's Monitor I and Monitor III Crypto data collection (>V2R3 only) is extended to recognize performance measurements from Cryptographic Express8S Hardware Security Module (HSM), configured as Crypto Express8S Coprocessor (CEX8C), Crypto Express8S Accelerator (CEX8A) or Crypto Express8S PKCS11 Coprocessor (CEX8P) type on IBM z16. Cryptographic Express8S HSM measurements are stored in the existing Cryptographic Data Section of SMF record 70 subtype 2 and Monitor III ERBCRYG3 - Cryptographic Hardware Data Table (>V2R3 only). +--------------------------------------------------------------+ >>>>> SMF RECORD TYPE 70 SUBTYPE 2 - CRYPTO ACTIVITY <<<<< Field R7023CT of the Cryptographic Coprocessor Data Section contains the crypto processor type, which can be 3 = PCICC, 5 = PCIXCC, 7 = CEX2C, 9 = CEX3C, 10 = CEX4C , 11 = CEX5C, 12 = CEX6C, 13 = CEX7C, 14 = CEX8C Field R7024CT of the Cryptographic Accelerator Data Section contains the crypto processor type, which can be 4 = PCICA, 6 = CEX2A, 8 = CEX3A, 10 = CEX4A , 11 = CEX5A , 12 = CEX6A, 13 = CEX7A, 14 = CEX8A Field R7025CT of the Cryptographic PKCS11 Coprocessor Data Section contains the crypto processor type, which can be 10 = CEX4P , 11 = CEX5P , 12 = CEX6P, 13 = CEX7P, 14 = CEX8P +--------------------------------------------------------------+ >> MONITOR III ERBCRYG3 - CRYPTOGRAPHIC HARDWARE DATA TABLE (>V2R3 only) << Field APType of the CRYMD Table Entry Section contains the Crypto processor type, which can be: 11 = CEX5S, 12 = CEX6S, 13 = CEX7S, 14 = CEX8S Field MapTypeof the CRYMD Table Entry Section contains the mapping type, which can be: 8 = Accelerator mode, 9 = coprocessor mode (CCA), 10 = XCP mode (PKCS11)
Problem conclusion
Temporary fix
Comments
KEYWORD: SMFREC/K E3931/K
APAR Information
APAR number
OA59874
Reported component name
RMF DATA GATHER
Reported component ID
566527401
Reported release
7C0
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / New Function / CST /
Xsystem
Submitted date
2020-07-02
Closed date
2022-05-12
Last modified date
2022-06-08
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ08454 UJ08455 UJ08456
Modules/Macros
ERBCRYG3 ERBMFDCY ERBSMF70 GRBMFDCY
| SA380667XX |
Fix information
Fixed component name
RMF DATA GATHER
Fixed component ID
566527401
Applicable component levels
R7B0 PSY UJ08456
UP22/05/26 P F205
R7C0 PSY UJ08455
UP22/05/26 P F205
R7D0 PSY UJ08454
UP22/05/26 P F205
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.