A fix is available
APAR status
Closed as program error.
Error description
Post IPL, a command was entered on the System Console (SYSCONS HMC Operating System Messages window) that resulted in message IEE624I SYSTEM CONSOLE INPUT REJECTED, ISSUE VARY CN(*),ACTIVATE COMMAND TO ENABLE SYSTEM CONSOLE COMMUNICATIONS Following this message, an ABEND0C4 occurred in the SYSCONS Listener Exit, disabling the exit and preventing further non- Priority SYSCONS commands. An IPL is required to reactivate the SYSCONS exit.
Local fix
To avoid the problem, do any of the following... 1. IPL with a CONSOLxx CONSOLE DEVNUM(SYSCONS) with ALLOWCMD(Y) 2. Ensure the first SYSCONS command issued post IPL is VARY CN(*),ACTIVATE If the problem has already occurred, perform #2 above and check the SYSCONS Priority Box before issuing commands.
Problem summary
**************************************************************** * USERS AFFECTED: * * All z/OS 2.2 (HBB77A0) and above * * environments where commands are entered * * on the System Console (SYSCONS). * * * **************************************************************** * PROBLEM DESCRIPTION: * * ABEND0C4 from the SYSCONS Listener * * Exit followed by disablement of the * * exit. * * * **************************************************************** * RECOMMENDATION: * * Apply the appropriate PTF -or- utilize the * * LOCAL FIX. * * * **************************************************************** A command was entered on the System Console without proper authority resulting in message IEE624I that was immediately followed by an ABEND0C4 from the SYSCONS Listener Exit. This ABEND will be followed by disablement of the exit.
Problem conclusion
The SYSCONS Listener Exit has been modified to avoid the subject ABEND and disablement following message IEE624I.
Temporary fix
Comments
APAR Information
APAR number
OA59801
Reported component name
COMM TASK
Reported component ID
5752SC1CK
Reported release
7B0
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-06-17
Closed date
2020-07-31
Last modified date
2020-09-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ03655 UJ03656 UJ03657
Modules/Macros
IEAVC600
Fix information
Fixed component name
COMM TASK
Fixed component ID
5752SC1CK
Applicable component levels
R7A0 PSY UJ03657
UP20/08/12 P F008 ¢
R7B0 PSY UJ03655
UP20/08/12 P F008 ¢
R7C0 PSY UJ03656
UP20/08/12 P F008 ¢
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"7B0"}]
Document Information
Modified date:
02 September 2020