A fix is available
APAR status
Closed as program error.
Error description
Extra data validity checking introduced in OA56174 is only effective if DEBUG BUFFER is active.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: All users of zSecure Alert started task * * (C2POLICE) running the program with PTF for * * APAR OA56174 applied. * **************************************************************** * PROBLEM DESCRIPTION: zSecure Alert started task might * * consume an excessive amount of the * * central processor time. * **************************************************************** * RECOMMENDATION: Apply the PTF provided and review the * * documentation updates. * **************************************************************** When zSecure Alert started task (C2POLICE) encounters an invalid or incomplete SMF event data in its internal buffers, the program starts to use an excessive amount of the central processor time.
Problem conclusion
zSecure Alert has been modified so that it does not impose a high CPU load in cases where incomplete or invalid data related to SMF events are encountered. Please note the documentation updates as provided by the APAR tracking comment data.
Temporary fix
Comments
APAR Information
APAR number
OA58780
Reported component name
ZSEC BASE,ADMIN
Reported component ID
5655T0100
Reported release
230
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-12-09
Closed date
2020-01-15
Last modified date
2020-02-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ01802 UJ01807 UJ01808
Modules/Macros
C2PIORTN
Fix information
Fixed component name
ZSEC BASE,ADMIN
Fixed component ID
5655T0100
Applicable component levels
R230 PSY UJ01802
UP20/01/17 P F001
R231 PSY UJ01807
UP20/01/17 P F001
R240 PSY UJ01808
UP20/01/17 P F001
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSPQTM","label":"IBM Security zSecure Admin"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"230","Edition":"","Line of Business":{"code":"LOB24","label":"Security Software"}}]
Document Information
Modified date:
16 August 2024