IBM Support

OA58757: "$HASP430 INCOMPATIBLE SUBSYSTEM INTERFACE -- RC=08" WHEN STARTING JES2 AT V2R4

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When IPLing z/OS V2R4, JES2 may fail to initialize if the ICSF
    module CSNEKRR2 is not part of the LNKLST. This module is
    mistakenly considered a requirement of JES2 V2R4.
    
    KNOWN IMPACT:
    JES2 initialization will not complete.
    
    VERIFICATION STEPS:
    1. $HASP875 issued at start time
    2. "$HASP430 INCOMPATIBLE SUBSYSTEM INTERFACE -- RC=08"
    3. SCSFMOD0 not in LNKLST concatenation
    

Local fix

  • BYPASS/CIRCUMVENTION:
    To bypass, add the SCSFMOD0 to the LNKLST concatenation so that
    CSNEKRR2 can be located.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All users of HJE77C0.                                        *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * JES2 is unable to find module CSNEKRR2                       *
    * and fails to start.                                          *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    If ICSF library CSF.SCSFMOD0 is not installed or is not in
    LNKLST concatenation, JES2 is not able to find module
    CSNEKRR2 and, as a result, fails to start.
    

Problem conclusion

  • TYPE/RESTART (WARM) IPL/REQUIRED (YES) CLPA (YES)
    
    CLPA is needed only if HASCxxxx modules currently reside in
    the pageable link pack area (PLPA).
    
    JES2 initialization code was changed to allow JES2 to start
    even if module CSNEKRR2 is not found.
    
    Note that JES2 SPOOL Encryption/Compression support will not
    be able to function without the presence of module CSNEKRR2.
    
    Additionally, APAR OA58757 is a conditioning APAR for JES2
    APAR OA57466:  The HASPIRDA and HASPMSG modules were changed
    to prevent a JES2 member that does not have full JES2 SPOOL
    Encryption/Compression support installed from joining a MAS
    where such support has ever been enabled.
    
    Searchable keywords:
    
     - msgHASP430
     - $HASP720
     - msgHASP720
    
    **********************************************************
    *                                                        *
    *  The PTF for this APAR must be installed and active    *
    *  on all members in the MAS before APAR OA57466 can be  *
    *  applied to any member within the MAS.                 *
    *                                                        *
    **********************************************************
    
    APAR OA58757 prereq's (and sup's) for FMID HJE77C0:
    Pre's: CA57976
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA58757

  • Reported component name

    JES2

  • Reported component ID

    5752SC1BH

  • Reported release

    7C0

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-12-03

  • Closed date

    2020-01-30

  • Last modified date

    2021-10-06

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UJ01976

Modules/Macros

  • HASCSRIC $CADDR   HASPPRPU HASPIRDA HASPIRSI HASMCADR HASPMSG
    HASCSRIP
    

Fix information

  • Fixed component name

    JES2

  • Fixed component ID

    5752SC1BH

Applicable component levels

  • R7C0 PSY UJ01976

       UP20/02/12 P F002

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.