A fix is available
APAR status
Closed as program error.
Error description
CBDA383I surfaces during HCD activate for devices that were explicitly connected to Operating System configurations or whose OS definitions (in the part of the READ-ONLY specification) were changed before the application of a PTF for OA54706.
Local fix
RECOVERY ACTION: 1) Run an OS report to find out which devices are getting the CBDA383I. 1A) Start HCD with current IODF, 1B) Go to Option 3 -> 1, 1C) Put a slash in front of 'OS report' only, allow '1' (YES) for 'Limit reports', press Enter, and choose 'OS device report'. 1D)Allow HCD to submit a batch job and then check its output (at the end) for presence of CBDA383I messages. 2) Change/reconnect those devices in order to update the control blocks.
Problem summary
**************************************************************** * USERS AFFECTED: * * HCD users of D/T2107 storage subsystems defining DASD 3390 * * devices as Read-Only * **************************************************************** * PROBLEM DESCRIPTION: * * The data structure in the IODF that * * represents a device with the READ-ONLY * * parameter contains a length that is * * larger than permitted by the UDT. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
The maximum length allowed for the READ-ONLY parameter in HCD was increased to avoid CBDA383I message and also to allow future growth. KEYWORDS: D/T2107
Temporary fix
Comments
APAR Information
APAR number
OA58503
Reported component name
DEVICE SUPPORT
Reported component ID
5695DF111
Reported release
230
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-10-15
Closed date
2020-03-19
Last modified date
2020-08-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ02420 UJ02421 UJ02423
Modules/Macros
CBDUS002 CBDES002
Fix information
Fixed component name
DEVICE SUPPORT
Fixed component ID
5695DF111
Applicable component levels
R230 PSY UJ02420
UP20/07/15 P F007
R220 PSY UJ02423
UP20/07/15 P F007
R240 PSY UJ02421
UP20/07/15 P F007
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"230","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
05 August 2020