Error description

  • TSO PARMLIB UPDATES
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All TSO/E Users                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: There is no way to set or disable       *
    *                      LOGON timeout when users are being      *
    *                      prompted during a LOGON session.        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    There is no way to change or disable the 5 minute LOGON
    prompting timeout value.
    This causes problems in some environments.
    

Problem conclusion

  • This support allows for setting a LOGON timeout value or
    disabling timeout.
    It has been implemented in V2R4.  Lower releases have been
    updated to tolerate the new keyword to allow sharing of the
    Parmlib member.
    Parmlib member IKJTSOxx will now allow setting a specific
    timeout value.  This support can also be disabled.
    The following book will be updated:.
    
    z/OS MVS Initialization and Tuning Reference (SA23-1380)
    Section : IKJTSOxx (TSO/E commands and programs)
    Subsection: Statements and parameters for IKJTSOxx
    
    LOGON
      TIMEOUT - Specifies a value between 0 and 255 denoting how
                many minutes TSO LOGON prompting will be allowed
                before the LOGON session is terminated. If 0 is
                specified no timeout will occur.  If not specified,
                5 minutes will be the default.
    
      Note: If the TIMEOUT value is routed from a system that does
            not support TIMEOUT, the receiving system will set the
            default of 5 minutes.
    
    
    FIXCAT :  ZOS0204C/K ZOS0205C/K ZOS0301C/K
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA57937

  • Reported component name

    TSO/E SCHEDULAR

  • Reported component ID

    566528502

  • Reported release

    7C0

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-07-12

  • Closed date

    2019-07-31

  • Last modified date

    2023-04-12

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UJ00270 UJ00271 UJ00275

Modules/Macros

  •    IKJEFLPU IKJPRMPK IKJPRM08 IKJTSVT
    

Publications Referenced
SA231380XX    

Fix information

  • Fixed component name

    TSO/E SCHEDULAR

  • Fixed component ID

    566528502

Applicable component levels

  • R7A0 PSY UJ00275

       UP19/08/14 P F908

  • R7B0 PSY UJ00270

       UP19/08/14 P F908

  • R7C0 PSY UJ00271

       UP19/08/14 P F908

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"7C0"}]

Document Information

Modified date:
12 April 2023