Error description
See APAR Abstract.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Users of HBB7790 and above with IEASYSxx * * RUCSA defined wishing to identify software * * that faults on user key CSA storage. * * * **************************************************************** * PROBLEM DESCRIPTION: * * GTF trace records are not collected * * for RUCSA faults as described in * * the z/OS Migration publication. * * * **************************************************************** * RECOMMENDATION: * **************************************************************** The 'Removal of user key common areas' section of the Migration publication documents steps that can be taken to capture GTF trace records to assist in identifying software that faults on user key CSA storage when IEASYSxx RUCSA is defined. These steps do not work as documented for RUCSA faults. Note: 'RUCSA faults' refer to faults on user key CSA storage when IEASYSxx RUCSA is defined.
Problem conclusion
A new RSM trace event (RUCSAFLT) is introduced to trace RUCSA fault events and is documented in the z/OS MVS Diagnosis: Tools and Service Aids publication. In addition, new DIAGxx TRAPS NAME(IARRUCSAFLT) can be set to issue a retry-able C0D abend whenever a RUCSA fault occurs. Note: Unlike the RSM trace event (RUCSAFLT) that will be captured for all RUCSA (resolved and unresolved) faults, the retry-able C0D abend will only be issued when the faulter does not have SAF read authority to CLASS(FACILITY) PROFILE(IARRSM.RUCSA). The new IARRUCSAFLT trap is documented in the z/OS MVS Initialization and Tuning Reference. The new retry-able C0D abend will have a reason code of 05005C00 and is documented in the z/OS MVS System Codes publication. The following migration actions are documented in either the z/OS Migration or z/OS Upgrade Workflow publication to assist in identifying software that faults on user key CSA storage when IEASYSxx RUCSA is defined: Request a SYSRSM component trace with OPTIONS('RUCSAFLT') specified to request tracing of user key CSA storage faults when a RUCSA is defined. For more information on requesting and viewing component trace, see the 'Component trace' section of z/OS MVS Diagnosis: Tools and Service Aids. Each RUCSAFLT trace record will include the faulting virtual storage address (VSA) in RUCSA and the faulter's PSWE (16-byte PSW). For example: SYSNAME MNEMONIC ENTRY ID TIME STAMP DESCRIPTION ------- -------- -------- --------------- ----------- S7A0 RUCSAFLT 0000001B 20:21:24.568179 RUCSA Fault FUNC1... FLTAESEG Addr Space Seg Faults JOBN1... RSJRUE9B ASID1... 0022 PLOCKS.. 08004000 JOBN2... RSJRUE9B ASID2... 0022 RLOCKS.. 08004000 KEY..... 0036 ADDR.... 02782808 ALET.... 00000000 0500 KEY..... 002F ADDR.... 09F00801 ALET.... 00000000 KEY..... 0086 ADDR.... 0276A390 ALET.... 00000000 07047001 80000000 00000000 091D577A In the above example, key 002F contains the faulting VSA in RUCSA and key 0086 contains the faulter's PSWE. The last half of the faulter's PSWE can be used to identify the software that faulted on user key CSA storage when a RUCSA is defined. There may be cases when the above RUCSAFLT trace record may not be enough to identify the faulting software. For example, when the software is no longer loaded in the address identified by key 0086. For those cases, you can perform the following steps: - Run with TRAPS NAME(IARRUCSAFLT) specified on an active DIAGxx parmlib member. Any software attempting to fault on user key CSA storage when a RUCSA is defined and does not have SAF READ authority to CLASS(FACILITY) PROFILE(IARRSM.RUCSA) will result in a C0D-05005C00 abend. For more information on the IARRSM.RUCSA profile, see the documentation updates for APAR OA56180 located at http://publibz.boulder.ibm.com/zoslib/pdf/OA56180.pdf - Set the following example SLIP trap to produce an SVC dump when the C0D-05005C00 abend occurs. SLIP SET,ID=C0DA,C=C0D,A=SVCD,RE=05005C00, SDATA=(ALLNUC,LPA,LSQA,PSA,RGN,SQA, ALLPSA,NUC,TRT,CSA,SUM,SWA), END Note: Register 2 is preloaded with the faulter's VSA and register 3 is preloaded with the faulting VSA in RUCSA prior to taking the COD-05005C00 abend. Register 2 can be used to identify the faulting software. Consider adding the MATCHLIM parameter if you want the above SLIP trap to hit more than once before becoming disabled. Additional Search Keywords: ZOS0204C/K ZOS0205C/K ZOS0301C/K ABENDC0D RSN05005C00
Temporary fix
Comments
APAR Information
APAR number
OA57889
Reported component name
RSM - REAL STOR
Reported component ID
5752SC1CR
Reported release
7A0
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-07-02
Closed date
2019-07-30
Last modified date
2023-04-12
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ00221 UJ00222 UJ00224 UJ00225
Modules/Macros
IAXZIFTE IAXZITBL IGVDGNB IGVDGNTM IAXFS IAXMJ
| SA231380XX | SA380665XX | GA320889XX | GA320905XX |
Fix information
Fixed component name
RSM - REAL STOR
Fixed component ID
5752SC1CR
Applicable component levels
R790 PSY UJ00225
UP19/08/14 P F908
R7A0 PSY UJ00224
UP19/08/14 P F908
R7C0 PSY UJ00222
UP19/08/14 P F908
R7B0 PSY UJ00221
UP19/08/14 P F908
Fix is available