A fix is available
APAR status
Closed as program error.
Error description
NVINFO CANZLOG PRINT fails with message: DSI203I DATE OR TIME VALUE IS OMITTED OR NOT VALID
Local fix
Specify a PRINT starting from date/time that is contained within the CANZLOG archives.
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM Tivoli NetView for z/OS * * V6R1 and above. * **************************************************************** * PROBLEM DESCRIPTION: When Canzlog archives are being used * * (ARCHIVE.HLQ is set to something other * * than *NONE*), and a FROM date/time is * * specified for a PIPE CZR (which is used * * by the PRINT function which is invoked * * by NVINFO) that is earlier than the * * earliest date/time available in the * * archives, the PIPE fails and msgDSI203I * * is issued. Users should not have to * * know the date/time of the earliest * * record in Canzlog archives. * **************************************************************** When archives are used and a date/time earlier than the earliest available date/time in the archives is requested of module DSI4LAPM, it just gives a "not found" return code back to the caller. In the case of PIPE CZR, module DSIPICZR calls module DSI4LAPN, which calls DSI4LAPM. Module DSI4LAPN considers this "not found" condition as an error, which it gives back to DSIPICZR. As a result, module DSIPICZR issues message DSI203I and fails the pipe. Also, there are four numbered bullets at the end of the Usage Notes in the English online help for PIPE CZR that do not belong.
Problem conclusion
Module DSI4LAPM is being changed to set reason codes even for its "not found" error code, one of which being for a "too small" condition (meaning the "from" date/time value is too early). When it sets that reason code, it will also return the date/time of the earliest time stamp in the master index to the caller. Module DSI4LAPN is being changed such that when the "too small" reason code is returned, it will just call DSI4LAPM again, since the "from" date/time value will now be correct. As a result, searching will begin at the earliest record. Also, the following documentation changes should be made: The description of the CZR stage in the IBM Tivoli NetView for z/OS V6R2M1 Programming: Pipes manual (SC27-2859-06) should be changed as follows: - The last sentence (the one starting with "Be careful not to specify a time") in the description of the TIME parameter should be removed. - The last sentence in the third bullet under Usage Notes which begins with "However, if the time is earlier" should be changed to read as follows: When the time in the TIME argument is earlier than any record in the Canzlog log and the search is downward (+), then the CZR stage starts with the earliest available record. The description of the PRINT (NCCF) command in the IBM Tivoli NetView for z/OS V6R2M1 Command Reference Volume 2 (O-Z) (SC27-2848-06) should be changed as follows: - The last bullet under Usage Notes (which has a heading "Archiving and start time specifications") should be entirely removed. The description of message DSI203I in the IBM Tivoli NetView for z/OS V6R2M1 Messages and Codes Volume 1 (AAU-DSI) (GC27-2856-07) should be changed as follows: - The Note (which starts "If the message is issued from the PRINT command") should be entirely removed. The online help for the following is being changed to reflect the above: - PIPE CZR - NCCF PRINT (English only) - DSI203I (English only) Also, the English version of the online help for PIPE CZR is being changed to no longer have the extraneous four numbered bullets after the Usage Notes.
Temporary fix
Comments
APAR Information
APAR number
OA57578
Reported component name
AUTO CNTL NETV
Reported component ID
5698LSA01
Reported release
12B
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-05-14
Closed date
2020-08-28
Last modified date
2020-10-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ03836 UJ03837 UJ03838 OA60216
Modules/Macros
DSI20 DSI4LAPM DSI4LAPN EUYPICHP EUYPRINT
Fix information
Fixed component name
AUTO CNTL NETV
Fixed component ID
5698LSA01
Applicable component levels
R12B PSY UJ03836
UP20/09/02 P F009
R12E PSY UJ03837
UP20/09/02 P F009
R12J PSY UJ03838
UP20/09/02 P F009