IBM Support

OA57408: APAR OA54814 SHIPPED SYSTEM LOGGER'S USE OF ZHYPERWRITE AS ACTIVE BY DEFAULT. IT WILL BE CHANGED TO INACTIVE BY DEFAULT.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The purpose of this APAR is to change the current default
    enablement of Logger Hyperwrite from YES to NO.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All z/OS 2.2 and above System Logger                         *
    * environments with APAR OA54814 applied.                      *
    *                                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * System Logger's use of zHyperWrite is                        *
    * active by Default ( ALLOWUSE(YES) )                          *
    *                                                              *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * See BYPASS/CIRCUMVENTION.                                    *
    *                                                              *
    ****************************************************************
    
    APAR OA54814 shipped System Logger's use of zHyperWrite as
    active by Default ( ALLOWUSE(YES) ).
    

Problem conclusion

  • The System Logger Default use of Hyperwrite has been changed
    from ALLOWUSE(YES) to ALLOWUSE(NO).
    
      z/OS MVS Initialization and Tuning Reference
      --------------------------------------------
    
      :
      IXGCNFxx member
       :
       Specifying the IXGCNFxx members
        :
        Syntax format of IXGCNFxx
          :
          MANAGE
            :
            HYPERWRITE
              ALLOWUSE(YES | NO)
     |                       --
            :
       :
       Statements and parameters for IXGCNFxx
         :
         MANAGE
          Provides the resource management policy for system logger.
         :
         HYPERWRITE
          Specifies the system logger policy on the system for IBM
          zHyperWrite data replication use for log stream data sets.
    
          ALLOWUSE(YES | NO)
     |                   --
          YES
           Indicates that use of IBM zHyperWrite data replication
           is allowed as system logger writes to certain log stream
           data sets on the particular system as follows:
            - staging data sets for DASDONLY type log streams,
            - offload data sets for both the DASDONLY type and
           Coupling Facility structure-based type log streams.
          :
          :
          NO
           Indicates that use of IBM zHyperWrite data replication is
           not allowed for any system logger log stream data sets on
           the particular system with this specification.
    
     |    Default:  NO
    
       z/OS MVS System Messages
      -------------------------
    
       The (IXG607I) formatted portion of IXG601I message issued
       in response to DISPLAY LOGGER,IXGCNF,MANAGE  command now
       includes MANAGE HYPERWRITE ALLOWUSE specification.
       :
       LOGGER              PARAMETER OPTIONS
          KEYWORD           SOURCE    VALUE
       -----------------   -------------------
         MANAGE
          OFFLOAD
           ALLOCAHEAD       DEFAULT    YES
           USEOFFLOADMIN    DEFAULT    YES
          STAGING
           USESTAGINGMIN    DEFAULT    YES
          HYPERWRITE
     |     ALLOWUSE         DEFAULT    NO
          LOGRCDS
           ALLOWACCESS      DEFAULT    YES
      :
    

Temporary fix

Comments

  • ×**** PE19/09/10 FIX IN ERROR. SEE APAR OA58287  FOR DESCRIPTION
    ×**** PE22/01/06 FIX IN ERROR. SEE APAR OA62658  FOR DESCRIPTION
    

APAR Information

  • APAR number

    OA57408

  • Reported component name

    SYSTEM LOGGER

  • Reported component ID

    5752SCLOG

  • Reported release

    7B0

  • Status

    CLOSED PER

  • PE

    YesPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-04-30

  • Closed date

    2019-07-22

  • Last modified date

    2022-03-10

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UJ00118 UJ00132 UJ00133

Modules/Macros

  • IXGE3CNF IXGCNFXX
    

Publications Referenced
SA23138000SA38067700   

Fix information

  • Fixed component name

    SYSTEM LOGGER

  • Fixed component ID

    5752SCLOG

Applicable component levels

  • R7A0 PSY UJ00133

       UP19/08/07 P F908 {

  • R7B0 PSY UJ00118

       UP19/08/07 P F908 {

  • R7C0 PSY UJ00132

       UP19/08/07 P F908 {

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z\/OS"}],"Version":"7B0"}]

Document Information

Modified date: