A fix is available
APAR status
Closed as program error.
Error description
ABEND0C4 KLV$GMEM in CLASSIC with PTF(s) UA98401 and/or UA98402 applied.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All ITMS/ENGINE users. * **************************************************************** * PROBLEM DESCRIPTION: After UA97074, high CPU may be observed * * accompanied by contention for * * KLVEMRQN/KLVEMRRN. * * * * After UA98465, S0C4 abends may occur in * * Engine VTAM or XCF exits, for example, * * when logging on to the CUA. * **************************************************************** * RECOMMENDATION: Apply the PTF. * **************************************************************** Non-threadsafe updates to memory control blocks may lead to unpredictable behaviour including abends, high CPU, and resource contention on KLVEMRQN/KLVEMRRN. Code intended to provide more diagnostic information to aid debugging can try to access fetch-protected memory causing S0C4 abends.
Problem conclusion
ITMS/Engine was changed to: - make threadsafe updates to memory control blocks. - not access fetch-protected memory.
Temporary fix
Comments
APAR Information
APAR number
OA56915
Reported component name
CT/ENGINE
Reported component ID
5608A41CE
Reported release
630
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
YesSpecatt / Pervasive / Xsystem
Submitted date
2019-02-08
Closed date
2019-02-19
Last modified date
2019-03-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA98604
Modules/Macros
KLV$FMEM KLV$GMEM KLV$OWN KLVST200
Fix information
Fixed component name
CT/ENGINE
Fixed component ID
5608A41CE
Applicable component levels
R630 PSY UA98604
UP19/02/22 P F902 a
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.