A fix is available
APAR status
Closed as program error.
Error description
AB/S011E 702 FPZINLPA FPZPRRZV FPZRECOV COMPON=FPZ,COMPID=SCIQP,ISSUER=FPZMESTA,MODULE=FPZPRRZV+0EE6, Timing window seen by zFS and SMF logstream during IPL. Applications complete a Rendezvous before the zEDC cards are completely allocated from the PCIE initialization routine. ABEND=S011E,REASON=05050702 x'11E' x'XXXX0702' PCIEServiceFailure A failure occurred calling a PCIE routine. This is a generic return code generated because IQPPROPN failed with a return code = 79 and reason code = 42. The zEDC Rendezvous service should check that the compression services have completed initialization before allowing a successful rendezvous. In this case the rendezvous was completed but the subsequent open failed because the zEDC card had not completed the allocation process. ANALYSIS: From the C-Trace: JC0 PCIE 006B0001 14:43:56.120611 IQPPROPN Exit Open PCIE ASID...0012 TCB....007C2E88 PFID...0000 +0000 D6D7D5A7 20800000 00000000 00000000 00000000 000001EF 84800000 00000000 +0020 02A964A0 00000000 00000000 00000079 0D060042 || || <-rc/rsn This is the Open Failure with return code of x'79' and reason of x'42'. 79'X 'XXXX0042'X EINVAL JRINVALIDFUNCHAND The parameter is incorrect Specified Software Function Handle is not valid This handle is invalid because HWAM has not finished allocation of the zEDC card. There should be a subsequent trace that shows: JC0 PCIE 008B0009 14:43:56.121336 FPGPALLB Device Allocation OK ASID...0014 TCB....007F81B8 PFID...0000 KNOWN IMPACT: This is a timing window at initialization, zEDC compression services are being accessed before it has finished its initialization process. ABEND11E REASON05050702 RSN05050702
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Users at HBB7790 and above using zEDC * * compression services. * **************************************************************** * PROBLEM DESCRIPTION: * * zEDC compression processing could * * be requested before the zEDC control * * blocks have been fully initialized, * * causing an ABEND11E RSN0702. (ZEDC/K) * **************************************************************** * RECOMMENDATION: * **************************************************************** zEDC compression processing could be requested before the zEDC control blocks have been fully initialized. This can cause zEDC services to fail with ABEND11E RSN0702.
Problem conclusion
FPZ4RZV has been enhanced to fully check and verify that the software/hardware initialization is complete. A short delay (less than 1 minute) has been added to allow initialization time to complete. If after the delay we are still not fully initialized, FPZ4RZV will return to the caller with the existing RetCode = '8'X indicating that NoDevices are available. This should prompt the user to reissue the FPZ4RZV request. At IPL time this could be noticed as an increase in IPL time if a caller issues a call to PCIE services prior to PCIE initialization , ie. DB2 KEYWORDS: ZEDC/K
Temporary fix
Comments
×**** PE19/07/09 FIX IN ERROR. SEE APAR OA57878 FOR DESCRIPTION ×**** PE19/10/07 FIX IN ERROR. SEE APAR OA58457 FOR DESCRIPTION ×**** PE20/02/24 FIX IN ERROR. SEE APAR OA58457 FOR DESCRIPTION ×**** PE20/03/11 FIX IN ERROR. SEE APAR OA58457 FOR DESCRIPTION ×**** AE20/02/27 FIX IN ERROR. SEE APAR OA59155 FOR DESCRIPTION
APAR Information
APAR number
OA56880
Reported component name
SMF
Reported component ID
5752SC102
Reported release
7A0
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-02-06
Closed date
2019-05-14
Last modified date
2020-06-17
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA99287 UA99292 UA99298
Modules/Macros
FPZPRRZV FPZINIT
Fix information
Fixed component name
PCIE SERVICES
Fixed component ID
5752SCIQP
Applicable component levels
R790 PSY UA99298
UP19/05/30 P F905
R7A0 PSY UA99292
UP19/05/30 P F905
R7B0 PSY UA99287
UP19/05/30 P F905
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"7A0","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: