Error description

  • Early subtask detach triggers recursive abend processing during
    subtask termination in zSecure Alert.
    The following messages may be seen:
    IEA989I SLIP TRAP ID=X13E MATCHED. JOBNAME=C2POLICE
    IEC999I IFG0TC0A,IDACAT13,C2POLICE,C2POLICE
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of zSecure Alert.                  *
    ****************************************************************
    * PROBLEM DESCRIPTION: The zSecure Alert started task          *
    *                      (C2POLICE) might issue an ABENDS13E and *
    *                      a MSGIEC999I message.                   *
    ****************************************************************
    * RECOMMENDATION: Apply the PTF provided.                      *
    ****************************************************************
    When the zSecure Alert started task (C2POLICE) performs an
    environment refresh, it might issue an ABENDS13E and
    a MSGIEC999I message which begins with the text
    "IFG0TC0A,IDACAT13,C2POLICE...".
    

Problem conclusion

  • The zSecure Alert started task (C2POLICE) has been modified so
    that the environment refresh does not result in an ABENDS13E and
    no MSGIEC999I message is issued.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA56868

  • Reported component name

    ZSEC BASE,ADMIN

  • Reported component ID

    5655T0100

  • Reported release

    230

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-01-31

  • Closed date

    2019-02-27

  • Last modified date

    2019-03-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UA98673

Modules/Macros

  • C2PENVLP
    

Fix information

  • Fixed component name

    ZSEC BASE,ADMIN

  • Fixed component ID

    5655T0100

Applicable component levels

  • R231 PSY UA98673

       UP19/02/28 P F902

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSPQTM","label":"IBM Security zSecure Admin"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"230","Edition":"","Line of Business":{"code":"LOB24","label":"Security Software"}}]