OA56387: ABEND 018A IN BHIP1CCW.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Abend 018A in module BHIP1CCW with reason code 3BF20101 in Reg.
    0 and reason code 10 in reg. 15.
    
    3BF20101 - A program check occurred when the paging services was
    accessing the caller's service list (SL) entry.
    
    10 - The input ECB, TCB, or PSL/SSL failed validity checks.
    
    ANALYSIS:
    Register 3: If branch entry, caller's return address.
    Register 4: If LIST-FORMAT entry, address of the caller's
    erroneous page service list entry (PSL)
    Register 11: If LIST-FORMAT entry, address of the caller's first
    PSL/SSL entry.
    
    BHIP1CCW issues the ?PGSER macro with a FIX or FREE using a PSL.
    If the frame backing the PSL is stolen, a page fault can be
    encountered leading to the abend.  This is more likely to occur
    on a system that is memory constrained.
    
    VERIFICATION STEPS:
    In syslog, check for a PGM that is on the same page as
    the PSL
    
    Example from customer case:
    
    Reg. 11
    
    7DEBCC88.  7DEBCB88 7DEBCC87  00000200 2317E800 2317E817
               00000000
    
    7DEBCCA0.  23659000 236598B7 80000000 00000000  00000000
               00000000
    
    Reg. 4
    
    7DEBCC94.  2317E800
    
    
    From the Syslog:
    
    
    009C2E88  PGM    011 00000000_01BD20B6  00060011
                         04041001 80000000  7DEBC800 <--- page
                                                         with PSL.
    
    009C2E88 *RCVY  PROG  8403C000 2D000810 00000000
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users at HBB77A0 and above that use z/OS     *
    *                 HyperSwap                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: ABEND18A RSN 3BF20101 in BHIP1CCW       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    BHIP1CCW was using non-page fixed storage for a parameter list
    to PGSER and could encounter ABEND18A reason code 3BF20101.
    

Problem conclusion

  • BHIP1CCW is changed to use fixed storage for the parameter list
    when page fixing the CCW storage.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA56387

  • Reported component name

    IOS

  • Reported component ID

    5752SC1C3

  • Reported release

    7A0

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-10-25

  • Closed date

    2019-02-07

  • Last modified date

    2019-03-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UA98494 UA98495

Modules/Macros

  • BHIP1CCW
    

Fix information

  • Fixed component name

    IOS

  • Fixed component ID

    5752SC1C3

Applicable component levels

  • R7B0 PSY UA98494

       UP19/02/20 P F902

  • R7A0 PSY UA98495

       UP19/02/20 P F902

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7A0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7A0","Edition":"","Line of Business":{"code":"","label":""}}]