  • A device is defined with two CHPIDs - FA and FF, both paths are
    operational and actively used, as confirmed by the D M=DEV
    system command. However, the D M=CONFIG(xx) command flags one of
    the channel paths as NOT GENERATED, as it follows from
    MSGIEE097I below:
    .
      IEE097I 13.46.16 DEVIATION STATUS
                     FROM MEMBER CONFIGxx
      DEVICE      DESIRED   ACTUAL
      7900,FF      ONLINE   NOT GEND
    .
    The message is incorrect and should not be issued by the D
    M=CONFIG(xx) command processor
    
    ANALYSIS:
    A dump confirms that the flagged path is installed and used; the
    LISTU 7900 subcommand in IPCS returns:
      LPM...... 30    PIM...... 30
      CHPID.... FFFFFAFF  00000000
                    --==
    Yet the IEEMPDV1 module displays CHP FF as NOT GEND, because
    subroutine CHECPATH attempts to locate the CHP in the SCHCHPID
    string, immediately finds it at offset +0 (mask 80), and exits,
    keeping a default of NOTGEN.
    
    KNOWN IMPACT:
    The D M=CONFIG(xx) system command may report on a valid and
    installed CHPID as NOT GEND in the IEE097I message
    
    VERIFICATION STEPS:
    MSGIEE097I returns a DEV,CHP with ACTUAL=NOT GEND. However, the
    D M=DEV(dev) system command confirms that the CHP is installed.
    

Local fix

  • BYPASS/CIRCUMVENTION:
    no circumvention
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users at HBB7790 and above                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: The D M=CONFIG(xx) command output       *
    *                      in MSGIEE097I may show some device      *
    *                      paths as NOT GEND when they actually    *
    *                      are installed.                          *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    D M=CONFIG(xx) command ("display deviations") processing
    invokes module IEEMPDV1 to compare the actual system
    configuration with the desired configuration specified in the
    CONFIG(xx) parmlib member.  IEEMPDV1's logic to check device
    paths is faulty and may result in message IEE097I showing some
    paths as NOT GEND when they actually are installed.
    
     IEE097I hh.mm.ss DEVIATION STATUS FROM MEMBER CONFIGxx
     DEVICE      DESIRED   ACTUAL
     dddd,pp     ONLINE    NOT GEND
    
    The D M=DEV(dddd) command will show the correct actual
    state of the device paths.
    
    Other than incorrectly reporting a deviation in the
    configuration, there is no impact to the system.
    

Problem conclusion

Temporary fix

Comments

  • This APAR is being closed FIN with concurrence from the
    submitting customer. This means that a solution to this
    APAR is expected to be delivered from IBM in a release
    (if any) to be available within the next 36 months.
    

APAR Information

  • APAR number

    OA55390

  • Reported component name

    IOS

  • Reported component ID

    5752SC1C3

  • Reported release

    7A0

  • Status

    CLOSED FIN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-05-01

  • Closed date

    2018-05-03

  • Last modified date

    2018-05-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    MP RECONFIG

  • Fixed component ID

    5752SC1CZ

Applicable component levels

  • R7A0 PSN

       UP

  • R7B0 PSN

       UP

  • R790 PSN

       UP

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7A0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7A0","Edition":"","Line of Business":{"code":"","label":""}}]