APAR status
Closed as fixed if next.
Error description
A device is defined with two CHPIDs - FA and FF, both paths are operational and actively used, as confirmed by the D M=DEV system command. However, the D M=CONFIG(xx) command flags one of the channel paths as NOT GENERATED, as it follows from MSGIEE097I below: . IEE097I 13.46.16 DEVIATION STATUS FROM MEMBER CONFIGxx DEVICE DESIRED ACTUAL 7900,FF ONLINE NOT GEND . The message is incorrect and should not be issued by the D M=CONFIG(xx) command processor ANALYSIS: A dump confirms that the flagged path is installed and used; the LISTU 7900 subcommand in IPCS returns: LPM...... 30 PIM...... 30 CHPID.... FFFFFAFF 00000000 --== Yet the IEEMPDV1 module displays CHP FF as NOT GEND, because subroutine CHECPATH attempts to locate the CHP in the SCHCHPID string, immediately finds it at offset +0 (mask 80), and exits, keeping a default of NOTGEN. KNOWN IMPACT: The D M=CONFIG(xx) system command may report on a valid and installed CHPID as NOT GEND in the IEE097I message VERIFICATION STEPS: MSGIEE097I returns a DEV,CHP with ACTUAL=NOT GEND. However, the D M=DEV(dev) system command confirms that the CHP is installed.
Local fix
BYPASS/CIRCUMVENTION: no circumvention
Problem summary
**************************************************************** * USERS AFFECTED: Users at HBB7790 and above * **************************************************************** * PROBLEM DESCRIPTION: The D M=CONFIG(xx) command output * * in MSGIEE097I may show some device * * paths as NOT GEND when they actually * * are installed. * **************************************************************** * RECOMMENDATION: * **************************************************************** D M=CONFIG(xx) command ("display deviations") processing invokes module IEEMPDV1 to compare the actual system configuration with the desired configuration specified in the CONFIG(xx) parmlib member. IEEMPDV1's logic to check device paths is faulty and may result in message IEE097I showing some paths as NOT GEND when they actually are installed. IEE097I hh.mm.ss DEVIATION STATUS FROM MEMBER CONFIGxx DEVICE DESIRED ACTUAL dddd,pp ONLINE NOT GEND The D M=DEV(dddd) command will show the correct actual state of the device paths. Other than incorrectly reporting a deviation in the configuration, there is no impact to the system.
Problem conclusion
Temporary fix
Comments
This APAR is being closed FIN with concurrence from the submitting customer. This means that a solution to this APAR is expected to be delivered from IBM in a release (if any) to be available within the next 36 months.
APAR Information
APAR number
OA55390
Reported component name
IOS
Reported component ID
5752SC1C3
Reported release
7A0
Status
CLOSED FIN
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-05-01
Closed date
2018-05-03
Last modified date
2018-05-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
MP RECONFIG
Fixed component ID
5752SC1CZ
Applicable component levels
R7A0 PSN
UP
R7B0 PSN
UP
R790 PSN
UP
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7A0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7A0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
03 May 2018