A fix is available
APAR status
Closed as program error.
Error description
After installation of zSecure 2.3.0 on z/OS 2.3.0, when applications are shutting down, they receive an 0C4 abend indicating a problem with zSecure module C2PRIY02.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: All users of the zSecure Access Monitor * * started task. * **************************************************************** * PROBLEM DESCRIPTION: The zSecure Access Monitor started task * * might cause some running tasks to * * ABEND0C4 during termination. * **************************************************************** * RECOMMENDATION: Apply the PTF provided. * **************************************************************** The running applications/tasks might issue an ABEND0C4 during termination in cases where the Access Monitor started task (C2PACMON) is active.
Problem conclusion
The zSecure Access Monitor started task has been modified so it does not cause other running applications to ABEND0C4 during termination.
Temporary fix
Comments
×**** PE18/04/10 FIX IN ERROR. SEE APAR OA55262 FOR DESCRIPTION
APAR Information
APAR number
OA55059
Reported component name
ZSEC BASE,ADMIN
Reported component ID
5655T0100
Reported release
230
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-03-05
Closed date
2018-03-21
Last modified date
2018-05-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA95654
Modules/Macros
C2PXINIT
Fix information
Fixed component name
ZSEC BASE,ADMIN
Fixed component ID
5655T0100
Applicable component levels
R230 PSY UA95865
UP18/04/16 P F804
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSPQTM","label":"IBM Security zSecure Admin"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"230","Edition":"","Line of Business":{"code":"LOB24","label":"Security Software"}}]