NEW FUNCTION - z/OS system logger has been enhanced to allow the use of IBM zHyperWrite data replication when it is configured at your installation.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: * * Users of HBB77A0 and above releases * * using System Logger Services and using * * IBM zHyperWrite data replication * **************************************************************** * PROBLEM DESCRIPTION: * * New function. * **************************************************************** * RECOMMENDATION: * **************************************************************** New function.
Problem conclusion
Temporary fix
Comments
z/OS system logger has been enhanced to allow the use of IBM zHyperWrite data replication when it is configured at your installation. Refer to the HYPERWRITE specification in publication z/OS MVS Initialization and Tuning Reference topic "IECIOSxx (I/O related parameters)" for details, requirements, and enablement related to the IBM zHyperWrite data replication. Log stream data sets that system logger will allow IBM zHyperWrite data replication are: - staging data sets for DASDONLY type log streams, - offload data sets for both the DASDONLY type and Coupling Facility structure-based type log streams. Log stream data sets that system logger does NOT support using IBM zHyperWrite data replication are: - staging data sets for Coupling Facility structure-based type log streams. See the documentation information for more details concerning this system logger enhancement. Multi System Application info - Before installing the PTFs for APAR OA54814 on any system in the SYSPLEX, the PTFs for APAR OA55079 MUST be installed and active on every system that makes use of log streams in the SYSPLEX. The PTFs for the APAR OA54814 enhancement may be applied and activated on one system at a time in the sysplex. An IPL is required to activate the PTFs for APAR OA54814 on each system of the SYSPLEX, however, a rolling IPL is sufficient to accomplish the activation. Additional Searchable keywords: SYSPLEXDS D/T2107 MSGIXG601I MSGIXG607I DOCUMENTATION Info for APAR OA54814 - Summary publication updates- SA232300XX z/OS Summary of Message and Interface Changes SA231380XX z/OS MVS Initialization and Tuning Reference SA380666XX z/OS MVS System Commands SA380677XX z/OS MVS System Messages, Vol 10 (IXC-IZP) z/OS Summary of Message and Interface Changes +-- list of changes --+ SYS1.PARMLIB member IXGCNFxx - MANAGE statement has new HYPERWRITE ALLOWUSE specification SYS1.SAMPLIB IXGCNFxx member contains new default - MANAGE HYPERWRITE ALLOWUSE(YES) System Commands - SETLOGR MANAGE,HYPERWRITE,ALLOWUSE(YES|NO) System Messages - IXG601I message formatted portion (IXG607I) issued in response to DISPLAY LOGGER,IXGCNF ,MANAGE command will now include MANAGE HYPERWRITE ALLOWUSE specification z/OS MVS Initialization and Tuning Reference +--- LOCATION IN PUBLICATION -------------------------------+ +-- IXGCNFxx parmlib member, new MANAGE statement keywords--+ +-- new information in sections - --+ +-- Syntax format of IXGCNFxx --+ +-- Statements and parameters for IXGCNFxx --+ +-- A "+" in the left-hand column designates added text --+ IXGCNFxx member- Specifying the IXGCNFxx members Syntax format of IXGCNFxx . . . MANAGE . . . + HYPERWRITE + ALLOWUSE(YES | NO) + --- . . . Statements and parameters for IXGCNFxx MANAGE Provides the resource management policy for system logger. . . . + HYPERWRITE + Specifies the system logger policy on the system for IBM + zHyperWrite data replication use for log stream data sets. + + ALLOWUSE(YES|NO) + --- + YES + Indicates that use of IBM zHyperWrite data replication is + allowed as system logger writes to certain log stream data + sets on the particular system as follows: + - staging data sets for DASDONLY type log streams, + - offload data sets for both the DASDONLY type and + Coupling Facility structure-based type log streams. + + Note: system logger does NOT support IBM zHyperWrite + data replication for: + - staging data sets for Coupling Facility + structure-based type log streams. + + Refer to the HYPERWRITE specification in topic + "IECIOSxx (I/O related parameters)" for details, + requirements, and enablement related to the + IBM zHyperWrite data replication. + requirements, and enablement related to the + IBM zHyperWrite data replication. + + NO + Indicates that use of IBM zHyperWrite data replication is + not allowed for any system logger log stream data sets on + the particular system with this specification. + + Default: YES z/OS MVS System Commands +--- LOCATION IN PUBLICATION ----------------------------+ +-- SETLOGR MANAGE command new parameters --+ The parameters for SETLOGR MANAGE are - Syntax- Table. SETLOGR MANAGE Command < new options > SETLOGR MANAGE, . . . + { HYPERWRITE } + { ,ALLOWUSE(YES|NO) } . . . Parameters- . . . + + HYPERWRITE + Specifies the system logger policy on the system for IBM + zHyperWrite data replication use for log stream data sets. + Changes will take effect on any subsequent writes to the + supported log stream data sets. + + ALLOWUSE(YES|NO) + + YES + Indicates that use of IBM zHyperWrite data replication is + allowed as system logger writes to certain log stream data + sets on the particular system as follows: + - staging data sets for DASDONLY type log streams, + - offload data sets for both the DASDONLY type and + Coupling Facility structure-based type log streams. + + Note: system logger does NOT support IBM zHyperWrite + data replication for: + - staging data sets for Coupling Facility + structure-based type log streams. + + Refer to the HYPERWRITE specification in topic + "IECIOSxx (I/O related parameters)" for details, + requirements, and enablement related to the + IBM zHyperWrite data replication. + + NO + Indicates that use of IBM zHyperWrite data replication is + not allowed for any system logger log stream data sets on + the particular system with this specification. z/OS MVS System Messages +--- LOCATION IN PUBLICATION ----------------------------+ +-- changed Logger messages --+ +-- IXG601I, IXG607I --+ The (IXG607I) formatted portion of IXG601I message issued in response to DISPLAY LOGGER,IXGCNF ,MANAGE command now includes MANAGE HYPERWRITE ALLOWUSE specification. LOGGER PARAMETER OPTIONS KEYWORD SOURCE VALUE ----------------- -------- ------------------------------ MANAGE OFFLOAD ALLOCAHEAD DEFAULT YES USEOFFLOADMIN DEFAULT YES STAGING USESTAGINGMIN DEFAULT YES + HYPERWRITE + ALLOWUSE DEFAULT YES LOGRCDS ALLOWACCESS DEFAULT YES ×**** PE19/03/27 FIX IN ERROR. SEE APAR OA57187 FOR DESCRIPTION ×**** PE19/03/27 FIX IN ERROR. SEE APAR OA57187 FOR DESCRIPTION ×**** PE19/03/27 FIX IN ERROR. SEE APAR OA57187 FOR DESCRIPTION ×**** PE19/04/30 FIX IN ERROR. SEE APAR OA57408 FOR DESCRIPTION ×**** PE19/04/30 FIX IN ERROR. SEE APAR OA57408 FOR DESCRIPTION
APAR Information
APAR number
OA54814
Reported component name
SYSTEM LOGGER
Reported component ID
5752SCLOG
Reported release
7A0
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / New Function / SYSPLXDS /
Xsystem
Submitted date
2018-01-29
Closed date
2018-09-19
Last modified date
2019-07-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA97466 UA97467
Modules/Macros
IXGMLSAB IXGA1AUS IXGE1TPR IXGCNFXX IXGD2IN1 IXGD2WRT IXGYLSAB IXGP1DSP IXGL1SUX IXGA1SWT IXGE1TLX IXGILSAB IXGE3CNF IXGA1MM IXGD2RED IXGE1CNF IXGA1MTX IXGYSTBL
| SA23230000 | SA23138000 | SA38066600 | SA38067700 |
Fix information
Fixed component name
SYSTEM LOGGER
Fixed component ID
5752SCLOG
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7A0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7A0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
22 July 2019