A fix is available
APAR status
Closed as new function.
Error description
In support of NEW FUNCTION
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of HBB77A0 * **************************************************************** * PROBLEM DESCRIPTION: NEW FUNCTION: System parameter * * OSPROTECT specifies the operating * * system protection mode for * * unauthorized programs and users. * **************************************************************** * RECOMMENDATION: * **************************************************************** This APAR introduces the OSPROTECT system parameter which specifies the operating system protection mode for unauthorized programs and users. See the documentation for more information.
Problem conclusion
This APAR introduces the OSPROTECT system parameter which specifies the operating system protection mode for unauthorized programs and users. See http://publibz.boulder.ibm.com/zoslib/pdf/OA54807.pdf for full publication updates. This URL is case-sensitive. SA23-1380 - z/OS MVS Initialization and Tuning Reference The system parameter OSPROTECT is introduced. SA38-0667 - z/OS MVS System Management Facilities (SMF) The SMF30CAS_OA54589 field has been added at offset 188 (X'BC') in the Processor Accounting section of SMF record type 30. SA23-1394 - z/OS MVS Programming: Extended Addressability Guide The chapter on creating and using subspaces is updated and a section on authorized programs and subspaces is added. GA32-0905 - z/OS MVS Diagnosis: Tools and Service Aids In the "System trace" chapter, information about SSID 0151 has been added to the "SSRV trace entries" topic. GA32-0904 - z/OS MVS Diagnosis: Reference Information about octo frames has been added to the RSMDATA SUMMARY subcommand output. SA38-0665 - z/OS MVS System Codes System completion code 0C4 in the 0Cx section is updated. SA38-0673 - z/OS MVS System Messages, Vol 6 (GOS-IEA) The IEA987I message is added to indicate that a parameter value requires support that is not available on the system.
Temporary fix
Comments
NEW FUNCTION ×**** PE18/12/13 FIX IN ERROR. SEE APAR OA56640 FOR DESCRIPTION **** PTF in error. See apar OA56775 for PE description.
APAR Information
APAR number
OA54807
Reported component name
SUPERVISOR CONT
Reported component ID
5752SC1C5
Reported release
790
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / New Function / Xsystem
Submitted date
2018-01-29
Closed date
2018-06-13
Last modified date
2019-03-12
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA96477
Modules/Macros
IEADRIMS IEALCCAP IEAVEEXP IEAVEEXT IEAVEIO IEAVEPC IEAVEPCO IEAVERES IEAVESVC IEAVNIPX IEAVNP09 IEECB985 IGFPMCIH IHAIPA IHALCCA
SA23138000 | SA38066700 | SA23139400 | GA32090500 | GA32090400 |
SA38066500 | SA38067300 |
Fix information
Fixed component name
SUPERVISOR CONT
Fixed component ID
5752SC1C5
Applicable component levels
R7A0 PSY UA96477
UP18/07/23 P F807
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"790","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"790","Edition":"","Line of Business":{"code":"","label":""}}]