    An SCLM Language Definition includes an FLMALLOC statement with
    IOTYPE=P (partitioned data set).  Like with other IOTYPEs, the
    VIO keyword is supposed to override the usual rule for selection
    of the VIOUNIT based on the comparison of RECNUM against the
    MAXVIO value on the FLMCNTRL statement.  However this
    specification is being ignored, so VIO is selected (or not)
    solely on the size comparison.
    
    If DSNTYPE=LIBRARY is specified with VIO=N and a smaller RECNUM
    value, this can result in allocation failures when that
    processor is invoked.  For example:
    
      IKJ56893I DATA SET &SYSLMOD NOT ALLOCATED+
      IGD17040I ERROR IN DADSM PROCESSING ON VOLUME UNKNWN FOR DATA
                SET SYS17178.T091909.RA000.MYJOBN.SYSLMOD.H01
      HISTORIC RETURN CODE IS 196 DIAGNOSTIC INFORMATION IS 0C060090
    

Local fix

  • .
    When DSNTYPE=LIBRARY is required, update the associated Language
    Definition in the Project Definition (PROJDEFS) to use one of
    the following specifications:
    
     - CATLG=Y
    
     - RECNUM= some value larger than the MAXVIO value for this
       project.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of z/OS ISPF: SCLM                 *
    ****************************************************************
    * PROBLEM DESCRIPTION: A temporary PDS built for an IOTYPE=P   *
    *                      FLMALLOC on a COBOL build used VIO,     *
    *                      even though CATLG=N and VIO=N was       *
    *                      specified.                              *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    The VIO parameter is not being analyzed when determining what
    type of unit should be used for a temporary PDS specified
    by FLMALLOC.
    

Problem conclusion

Temporary fix

Comments

  • This APAR is being closed FIN (Fixed If Next) with concurrence
    from the submitting customer. This means that a fix to this
    APAR is expected to be delivered from IBM in a release (if
    any) to be available within the next 36 months.
    

APAR Information

  • APAR number

    OA53241

  • Reported component name

    ISPF Z/OS PDF&S

  • Reported component ID

    565504202

  • Reported release

    N02

  • Status

    CLOSED FIN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-06-28

  • Closed date

    2018-07-25

  • Last modified date

    2018-07-25

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

  • RN02 PSN

       UP

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"N02","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCDKBQ","label":"Program Development Facility (PDF)"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"N02","Edition":"","Line of Business":{"code":"","label":""}}]