IBM Support

OA51971: ABENDC78 RSN56 ABEND0C4 PIC10 PIC11 ABENDA03 WHEN RUNNING PROGRAM HSIPINQ V8R1

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Various abends are possible when running a multitasking DASD
    scan request using program HSIPINQ. (Each SCANDIR statement
    without the CATALOG keyword will generate a multitasking scan.)
    Multitasking was not used in releases older than V8R1.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IBM Tivoli Asset Discovery for z/OS V8.1 *
    *                 customers.                                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: SCANDIR requests may encounter various  *
    *                      abends such as S0C4, SC78 and SA03.     *
    *                      Message HSIP057E may appear to report   *
    *                      abend S000-522.                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    When the last volume of a scan request has been processed, the
    main task may proceed to either end the job step or start the
    next request (as appropriate) before the subtasks of the
    recently completed request have ascertained that there is no
    more work to do and terminate.
    
    Thus, subtasks may still exist when HSIPINQ attempts to
    terminate (abend SA03) or subtasks may attempt to access data
    structures of the next request (abend S0C4 or SC78-56) and/or
    message HSIP057E reporting an abend code of S000-522 which
    did not really occur - 522 being an internal code occurring
    when a volume cannot be matched to a subtask.
    

Problem conclusion

  • The main task will now wait until all of its subtasks have
    terminated before either ending the job step or initiating the
    next request.
    
    The internal response code of 522 - which was to signify that an
    indefinite wait or abend S522 had been avoided - is now replaced
    by x'AB' stored in a location not input to message HSIP057E.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA51971

  • Reported component name

    TIV ASSET DISC

  • Reported component ID

    5698B39TD

  • Reported release

    810

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-02-01

  • Closed date

    2017-02-12

  • Last modified date

    2017-03-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UA91073

Modules/Macros

  •    HSIPINQ
    

Fix information

  • Fixed component name

    TIV ASSET DISC

  • Fixed component ID

    5698B39TD

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSHT6S","label":"Tivoli Asset Discovery for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"810","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
24 June 2022