IBM Support

OA50911: IOS291I RC21 OR RC26 AFTER CHANGING PATHS TO DEVICES 16/08/09 PTF PECHANGE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Performing a dynamic IODF activate to delete paths from a
    logical control unit may not correctly update the SSCB path
    information. This makes it appear as though the old paths still
    exist, and may prevent new paths to be varied online.
    
    KNOWN IMPACT:
    This may prevent configuration data from being saved for new
    paths, which prevents them from being varied online for use.
    
    This can surface as errors such as Token NED Mismatch if the
    newly added paths connect to a different LSS, or this can
    surface as Maximum Number of Paths Exceeded when replacing some
    paths to an LSS.
    
     IEE103I UNIT D900 NOT BROUGHT ONLINE
     IEE763I NAME= IOSCCMSG CODE= 0000000800000021
     IOS291I  CONFIGURATION DATA COULD NOT BE READ ON PATH(D900,96)
     RC=21
     TOKEN NED MISMATCH HAS BEEN DETECTED
    
    or
    
     IOS291I  CONFIGURATION DATA COULD NOT BE READ ON PATH(D900,96)
     RC=26
     CONFIGURATION ERROR - MAXIMUM NUMBER OF PATHS EXCEEDED
     Some additional symptoms:
     0C4 in IOSVCUIN after HW dynamic activate to
     delete paths and delete devices
     UCB@ still in SSCB after dynamic activate.
    UCB's that were had paths deleted then hw/sw del are
    still in the SSCB.
     Also - NDCB will remain, even though the UCB will be deleted.
    
    
    VERIFICATION STEPS:
    1) Verify that the dynamic activate deleted CHPIDs from the
    devices in question.  This can be seen from message IOS502I
    
       IOS502I I/O CONFIGURATION CHANGED 268
       INVOKER = *MASTER*
       NEW IODF = HCDSUP.IODFAA
       EDT REBUILT, NEW EDT ID = 00
       CHPID 54 DELETED FROM DEVICE(S) IN CSS 0
       7B00-7BFF 7000-70FF 7D00-7DFF BF00-BFFF F700-F72F F770-F7FF
    
    2) Verify that the deleted CHPIDs are not seen in D M=DEV(dddd)
    
    3) Verify that the SSCB still has the deleted CHPIDs in the
       array at SSCB+x14
    
    PE INFORMATION:
    USERS AFFECTED:
    Users with SuperPAV support OA49090 applied, regardless of
    whether SuperPAV functionality is being exploited.  This affects
    any dynamic activates that include changing or removing paths to
    existing devices.
    
    These PTFs are:
    UA90997
    UA90996
    
    USER IMPACT:
    APAR OA49090 added a new function for SuperPAV support.  Part of
    the change introduced this new problem affecting dynamic
    activations.
    With the PTFs for OA49090 installed, it is possible to receive
    MSGIOS291I or MSGIOS1291I after a dynamic I/O configuration
    change when CHPIDs are removed, replaced or added to devices
    and control units, which may cause the new path(s) to fail to
    come online.
    If Dynamic Channel Path Management (DCM) is not used and your
    installation does not need to make dynamic I/O configuration
    changes that remove or change CHPID configurations, leaving the
    PTFs for APAR OA49090 installed should not result in errors. If
    you need to make path-related dynamic I/O configuration changes,
    you should consider removing the PTFs for OA49090.
    

Local fix

  • BYPASS/CIRCUMVENTION:
    Avoid performing dynamic activates that includes changing or
    removing paths to LCUs/Devices.
    
    RECOVERY ACTION:
    IPL, or:
    Perform a dynamic activate to delete all devices that have the
    problem.  Then perform another dynamic activate to re-add the
    problem devices.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users at HBB7790 and above with PTFs UA90996 *
    *                 or UA90997 installed.                        *
    ****************************************************************
    * PROBLEM DESCRIPTION: With OA49090 PTFs UA90996 or UA90997    *
    *                      installed, it is possible to receive    *
    *                      MSGIOS291I or MSGIOS1291I after a       *
    *                      dynamic I/O configuration change when   *
    *                      CHPIDs are removed, replaced or added   *
    *                      to devices and control units.           *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    After dynamic I/O configuration processing, if a CHPID is
    removed or replaced, processing fails to clean up self
    description information related to the affected CHPID.  This
    can cause a failure when attempting to read self description
    information for paths, resulting in MSGIOS291I CONFIGURATION
    DATA COULD NOT BE READ ON PATH(D900,96) RC=21 with reason
    text TOKEN NED MISMATCH HAS BEEN DETECTED or MSGIO291I
    CONFIGURATION DATA COULD NOT BE READ ON PATH(D900,96) RC=26
    with reason text CONFIGURATION ERROR - MAXIMUM NUMBER OF PATHS
    EXCEEDED.
    

Problem conclusion

  • Processing is changed to ensure that the self description data
    related to the affected CHPID is deleted or replaced.
    

Temporary fix

  • *********
    * HIPER *
    *********
    

Comments

APAR Information

  • APAR number

    OA50911

  • Reported component name

    IOS

  • Reported component ID

    5752SC1C3

  • Reported release

    7A0

  • Status

    CLOSED PER

  • PE

    YesPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-07-22

  • Closed date

    2016-08-12

  • Last modified date

    2016-11-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UA82497 UA82500

Modules/Macros

  • IOSRSCH
    

Fix information

  • Fixed component name

    IOS

  • Fixed component ID

    5752SC1C3

Applicable component levels

  • R7A0 PSY UA82497

       UP16/08/24 P F608 «

  • R790 PSY UA82500

       UP16/08/24 P F608 «

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7A0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7A0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
03 November 2016