A fix is available
APAR status
Closed as program error.
Error description
During creation of a new extent during CLOSE processing, any user blocks that have not been compressed and written out to the zedc compressed dataset yet will not be written out. This does not apply to BSAM processing since all outstanding WRITE requests must be CHECK'd for completion before CLOSE is issued. zEDC/k
Local fix
++APAR is available and requires an IPL Server: testcase.boulder.ibm.com Directory: /fromibm/mvs DSN: AA50061.HDZ1D10 (z/OS 1.13) BA50061.HDZ2210 (z/OS 2.1) CA50061.HDZ2220 (z/OS 2.2) DSORG: PS RECFM: FB LRECL: 80 BLKSIZE: 32720 Fix will remain on server for 5 days. Please contact Level2 support if fix is not seen on server.
Problem summary
**************************************************************** * USERS AFFECTED: Users writing to SAM extended format zEDC * * compressed data sets using QSAM. * **************************************************************** * PROBLEM DESCRIPTION: The potential exists for data loss * * when writing to a zEDC compressed * * data set using QSAM when CLOSE is * * issued and there exists a partial * * QSAM buffer that has not yet * * been written, and all allocated * * space in the data set is filled. * * In this case the unwritten partial * * buffer may not be written after * * CLOSE processing obtains the new * * extent for the data set. * * The problem does not apply to * * BSAM or other access methods. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
Problem has been corrected KEYWORDS: ZEDC/K
Temporary fix
********* * HIPER * *********
Comments
APAR Information
APAR number
OA50061
Reported component name
BASE ACCESS MET
Reported component ID
5695DF102
Reported release
210
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-03-08
Closed date
2016-03-24
Last modified date
2016-05-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA81134 UA81135 UA81136
Modules/Macros
IGG0201B
Fix information
Fixed component name
BASE ACCESS MET
Fixed component ID
5695DF102
Applicable component levels
RD10 PSY UA81134
UP16/04/05 P F604
R210 PSY UA81135
UP16/04/05 P F604
R220 PSY UA81136
UP16/04/05 P F604
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"210","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: