A fix is available
APAR status
Closed as new function.
Error description
New function in support of SDSF APAR PI43902
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: Installations running HBB7790 and above * **************************************************************** * PROBLEM DESCRIPTION: This APAR provides a PPT table update * * in support of SDSF APAR PI43902 * **************************************************************** * RECOMMENDATION: * **************************************************************** In support of SDSF APAR PI43902, the following entry is required in the IBM default Program Properties Table (PPT): PPT PGMNAME(HSFSRV00) KEY(4) NOSWAP
Problem conclusion
Temporary fix
Comments
This APAR adds the following entry to the IBM supplied default Program Properties Table (PPT) PPT PGMNAME(HSFSRV00) KEY(4) NOSWAP The following documentation is provided with this APAR: Document Name: MVS Initialization and Tuning Reference Document Number: SA23-1380 +--- LOCATION IN PUBLICATION ---------------------------+ | | | Chapter: SCHEDxx (PPT, master trace table, and | | abend codes for automatic restart) | | Section: Program properties table (PPT) | | | +-------------------------------------------------------+ Add the following entry into the table titled "IBM-Supplied Program Properties Table (PPT) Values". It should be inserted into the table in alphabetical order, by program name. Program Program Name Description NC NS PR ST ND BP Key 2P 1P NP NH CP -------- ----------- -- -- -- -- -- -- --- -- -- -- -- -- HSFSRV00 SDSF Data X 4 Gather
APAR Information
APAR number
OA48578
Reported component name
INITIATOR/TERM
Reported component ID
5752SC1B6
Reported release
7A0
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / New Function / Xsystem
Submitted date
2015-08-05
Closed date
2015-10-27
Last modified date
2016-01-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA79546 UA79547
Modules/Macros
IEFSDPPT
SA23138000 |
Fix information
Fixed component name
INITIATOR/TERM
Fixed component ID
5752SC1B6
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7A0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7A0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: