  • EXAMINE INDEXTEST DATATEST gives the following errors and
    ends with RC=8.  This is a minor error and we should get
    RC=4 if INDEXTEST and DATATEST are run together.
    
    for the INDEXTEST -
    IDC11724I DATA COMPONENT CA NOT KNOWN TO SEQUENCE SET
    RC=4
    for the DATATEST -
    IDC11724I DATA COMPONENT CA NOT KNOWN TO SEQUENCE SET
    IDC21703I MAJOR ERRORS FOUND BY DATATEST
    and gives RC=8 for entire EXAMINE job.
    
    The KSDS has nothing structurally wrong with it and processing
    will be the same in all cases. For the INDEX, a DSSPRINT shows
    the following correct seq. forward pointers:
    4DB----> 21A0---> 4DC .
    There is no Level2 pointer, to point to CI #21A0. You will get
    the same result if you read the KSDS Sequentially or do DIRECT
    READ to a record in CI #21A0.
    
    When INDEXTEST and DATATEST are run together, EXAMINE should be
    able to recognize that there is no structural damage and set the
    return code to 4.
    
    
    CATKEYS: IDC2015 IDCEXAM
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All z/OS 2.1 users of IDCAMS EXAMINE         *
    *                 using INDEXTEST and DATATEST.                *
    ****************************************************************
    * PROBLEM DESCRIPTION: EXAMINE INDEXTEST DATATEST returns RC=8 *
    *                      rather than RC=4 when it detects        *
    *                      an interrupted CA Split and issues      *
    *                      IDC11724I DATA COMPONENT CA NOT KNOWN   *
    *                      TO SEQUENCE SET.                        *
    ****************************************************************
    * RECOMMENDATION: Apply PTF.                                   *
    ****************************************************************
    Summary: Index test flag incorrectly passed to data test module.
    

Problem conclusion

  • Apply PTF and rerun job.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA47441

  • Reported component name

    DFSMS VSAM

  • Reported component ID

    5695DF106

  • Reported release

    210

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-03-30

  • Closed date

    2015-05-08

  • Last modified date

    2015-07-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UA77267 UA77268

Modules/Macros

  • IDCXM03
    

Fix information

  • Fixed component name

    ACCESS METHOD S

  • Fixed component ID

    5695DF103

Applicable component levels

  • R210 PSY UA77267

       UP15/06/02 P F506

  • R220 PSY UA77268

       UP15/06/02 P F506

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"210","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
01 July 2015