A fix is available
APAR status
Closed as program error.
Error description
Single Point of Failure (SPOF) raised on zEC12 or later machines configured with a single I/O Drawer showing reason: "10xxxxxxxxxxxxxxxxxxxxxx" The "10" bit indicates the I/O Cage is a single point of failure. This check should not apply to a single I/O Drawer. This message effects messages IOSPF108I, IOSPF154I, IOSPF208I, IOSPF254I, IOSPF308I, and IOSPF354I
Local fix
Ignore expected exception when single I/O drawer used
Problem summary
**************************************************************** * USERS AFFECTED: Users at HBB7780 and above using the * * IOS SPOF Health Check function or the * * IOSSPOF macro service. * **************************************************************** * PROBLEM DESCRIPTION: IOS Single Point of Failure service * * reports single points of failure * * which can not be corrected. * **************************************************************** * RECOMMENDATION: * **************************************************************** The SPOF check function starts out with a completely clear slate of possible issues to check but there are potential issues being checked and can be flagged which can not be corrected by the customer. . One example is the I/O drawer in a smaller machine that only supports one drawer.
Problem conclusion
Update the SPOF processing to ONLY check for components that are actionable by the customer and interesting to the processing. . The components that are being reported on are: processor book, fanout card, I/O domain and channel card. . Also, update the SPOF messages that have the component failure flags to include decoding of the bit string that is reported when there is a SPOF issue. . For example message IOSPF254I would be updated as follows: IOSPF254I Volumes vvvvv1 (sddd1) and vvvvv2 (sddd2) have all CHPIDs share a single point of failure, component indicators = xxxxxxxxxxxxxxxxxxxxxxxx (model dependent). ! Components: <components>
Temporary fix
Comments
. .
APAR Information
APAR number
OA47210
Reported component name
HEALTH CHECKER
Reported component ID
5752SCHZS
Reported release
780
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-02-26
Closed date
2016-06-17
Last modified date
2018-05-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA82020 UA82021 UA82022 UA82023 UA82024 UA82025
Modules/Macros
IOSDSPOF IOSHCSPM IOSIOSEN IOSIOSJP IOSVSPFR IOSVSPOF
| SA22763922 | SA38067603 | SA38067604 |
Fix information
Fixed component name
IOS
Fixed component ID
5752SC1C3
Applicable component levels
R7AJ PSY UA82023
UP16/07/06 P F607
R7A0 PSY UA82020
UP16/07/06 P F607
R78J PSY UA82024
UP16/07/06 P F607
R780 PSY UA82021
UP16/07/06 P F607
R79J PSY UA82025
UP16/07/06 P F607
R790 PSY UA82022
UP16/07/06 P F607
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"780","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"780","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: