IBM Support

OA46424: IEA794I SVC DUMP HAS CAPTURED: CODE=S0C4-04 DIAGNOSTIC DUMP MOD=GZDSSLM, CSECT=GZDVTOC , ZDMF/K

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • GZD3110E GZDSSLM  task has abended.
    GZD3111E - PSW at time of error: 070C0000 A3B2ECB0 00040004
    00000480
    GZD3112E - ABEND=S0C4  INTC=04 PASN=007F SASN=007F
    GZD3113E - PGM=GZDSSLM  Load Point=23B18E30 Offset=00015E80
    GZD3114E - Current CSECT=GZDVTOC
    GZD3115E - Data at PSW: 23B2ECAA - 001C5010 30001851 18F018E5
    GZD3116E - GPR 00-03 00000008 23942018 318441A0 00000168
    GZD3116E - GPR 04-07 223F18D8 223F11D0 1EA54320 00000004
    GZD3116E - GPR 08-11 317F6C40 1B0DE818 1B5F6010 23B2FBF8
    GZD3116E - GPR 12-15 23B2EB10 00048280 0000030B 00000000
    IEA794I SVC DUMP HAS CAPTURED:  505
    DUMPID=002 REQUESTED BY JOB (ZDMF    )
    DUMP TITLE=zDMF Diagnostic Dump - Mod=GZDSSLM , CSect=GZDVTOC ,
                code=S0C4-04
    
    Additional Symptom observered after the ABEND for some Groups in
    Mirror status.
    
    GZD1100I Command received via PC call from userid: SPGJIG
    GZD1101I DIVERT CICSMQX8 RETRY
    GZD0607I Divert cmd rejected for CICSMQX8: group busy.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All zDMF users.                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: Abend S0C4 in GZDVTOC +11E4             *
    ****************************************************************
    * RECOMMENDATION: Apply PTF and WARM start the servers.        *
    ****************************************************************
    GZDVTOC lookup table address can be accessed when set to zero
    if multiple GZDSSLM tasks operate on the same DWGDEV.
    

Problem conclusion

  • This apar serializes the DWGDEV VTOC lookup rebuild process
    and reduces the number of times the VTOC lookup table is
    rebuilt.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA46424

  • Reported component name

    ZDMF

  • Reported component ID

    ZDMF00001

  • Reported release

    325

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-11-03

  • Closed date

    2015-02-17

  • Last modified date

    2015-04-30

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    OA47080 UA76360

Modules/Macros

  •    GZDVTOC
    

Fix information

  • Fixed component name

    SOFTEK ZDMF

  • Fixed component ID

    694932D00

Applicable component levels

  • R325 PSY UA76360

       UP15/02/18 P F502

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SUPPORT","label":"IBM Worldwide Support"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2.5","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: