APAR status
Closed as fixed if next.
Error description
Dump Title: COMPON=ATR,COMPID=SCRRS,ISSUER=ATRBMDUM, MODULE=ATRSMSFG+1EF0 UNEXPECTED ERROR The error occurred in routine CBVError. This was after detecting that the SHE control block had been freed, showing SHE_Eyecatcher ATRSCshe The following message is issued when detecting a freed SHE: ATR246I RRS HAS DETECTED A SHE CONTROL BLOCK ERROR - UNEXPECTED ERROR DUMP REQUESTED This problem occured while processing Subordinate Forget. Investigation showed that there were multiple subordinate URs on the system going through syncpoint termination. The processing path for this subordinate UR in ATRSMSFG determined that SHE was complete. Then syncpoint for another subordinate UR in ATRTMARI found that the SHE was marked complete and freed it. ATRSMSFG attempted to access the SHE again after it had been freed, leading to the UE Additional Symptoms: The Unexpected Error may occur later in subordinate syncpoint forget, with dump title Dump Title: COMPON=ATR,COMPID=SCRRS,ISSUER=ATRBMDUM, MODULE=ATRXMSCB+D28A UNEXPECTED ERROR . . Another error that can be seen because of this timing window are dumps for: . COMPON=ATR,COMPID=SCRRS,ISSUER=ATRBMDUM,MODULE=ATRXMSCT+4D54 UNEXPECTED ERROR....... . and . COMPON=ATR,COMPID=SCRRS,ISSUER=ATRBMDUM,MODULE=ATRXMSCT+4B88 UNEXPECTED ERROR....... . The above two dumps were taken because of the same timing window that exists between ATRXMSCT and ATRTMARI. There is no real impact, aside from the dumps being taken. Additional potential UE dumps accompanied with ATR246I: ATRTMARI HBB7790+A63C ATRSMSPT UA70427+160A ATRSMSFG UA71504+235A ATRTMARI HBB7790+AD4A ATRTMARI HBB77A0+ADDA ATRXMSCB HBB7790+D486 ATRXMSCB HBB77A0+D456 Known Environment Sysplex Cascaded transaction processing with more than 1 subordinate URs cascaded on a system. Known Impact None. The SHE is freed during syncpoint forget processing. Each subordinate UR completes and cleans up successfully.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of RRS at HBB7705 and above that * * are running COMPLEX Sysplex Cascaded * * Transactions * **************************************************************** * PROBLEM DESCRIPTION: UNEXPECTED ERROR dump in RRS module * * ATRSMSFG during the internal clean up * * of a highly complex Sysplex Cascaded * * Transaction. * **************************************************************** * RECOMMENDATION: * **************************************************************** The internal clean up processing by RRS for a Sysplex Cascaded Transaction is incorrectly trying to reference a control block that has already been freed which is being detected and reported (via diagnostic code which generates the UNEXPECTED ERROR dump).
Problem conclusion
Temporary fix
Comments
This APAR is being closed FIN with the agreement from the customer and a fix will be developed and ship in a future release of the product.
APAR Information
APAR number
OA45765
Reported component name
RESOURCE RECOVE
Reported component ID
5752SCRRS
Reported release
770
Status
CLOSED FIN
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2014-07-31
Closed date
2014-08-10
Last modified date
2017-02-07
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
R770 PSN
UP
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"770","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"770","Edition":"","Line of Business":{"code":"","label":""}}]