Error description

  • New function.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of z/OS FlashCopy Manager.         *
    ****************************************************************
    * PROBLEM DESCRIPTION: New Function: Identify the device or    *
    *                      devices that are taking the longest to  *
    *                      establish FlashCopy Relationships.      *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    
    Support for displaying the times it takes to do a FlashCopy
    establish or withdraw was added in two places and is
    controlled by parameters specified in any of the jobs that
    call FLYAFC09 in the
    highqual.FCMGR.groupqual.NEW.JOBS and
    highqual.FCMGR.groupqual.CURRENT.JOBS PDS.  In
    highqual.FCMGR.groupqual.NEW.JOBS the following members may
    be changed to get the new message:
    
     A@WITHDR
     B@ESTABL
     Z@ESTABL
     Z@WITHDR
    
    Longest I/O:  Jobs that call FLYAFC09 may now specify an
    additional 'X' to receive an additional message, FLYAF604I
    that contains the device number and time of the device that
    took the longest to complete the I/O.  Edit the desired
    members and add an 'X' to the parms passed to FLYAFC09.
    Make sure that 'DELAY' is also specified.  For example:
    
    //***********************************************************
    //FREEZE  EXEC PGM=FLYAFC09,COND=(0,LT),
    //         PARM='FCFRX,F1=202601,DELAY,TON,X'
    
    When the job is run, look at the output for additional
    messages FLYAF602I and FLYAF604I that will contain the device
    number of the device that took the longest to complete the
    establish or withdraw I/O and the time it took. For example:
    
    FLYAF602I Time - T0=13:58:00.703  - T2=13:58:00.715
    FLYAF604I LONGEST I/O 0F45    0.010 seconds
    
    Each I/O: A message for each pair will be issued if the
    'TRACE' parameter is specified. The parameters 'TRACE' and 'X'
    are mutually exclusive but may be specified together.  Be sure
    'DELAY' is specified. If 'TRACE' is specified, expect a set of
    trace messages that will include a FLYAF903I message with the
    pair, the device number and the time it took to complete the
    I/O.  This option should only be used if for problem
    determination as the number of messages could be substantial
    given the number of tasks and establishes or withdraws done.
    

Problem conclusion

Temporary fix

Comments

  • z/OS FCM now support establish I/O timeing.
    ž**** PE15/11/23 FIX IN ERROR. SEE APAR OA46085  FOR DESCRIPTION
    

APAR Information

  • APAR number

    OA45511

  • Reported component name

    FLASH COPY MANA

  • Reported component ID

    5635FCP01

  • Reported release

    510

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / New Function / Serviceability

  • Submitted date

    2014-06-25

  • Closed date

    2014-07-23

  • Last modified date

    2015-11-23

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UA74274

Modules/Macros

  • FLYAFCA9 FLYAFCB9 FLYAFC09 FLYAFC19 HFCP510J
    

Fix information

  • Fixed component name

    FLASH COPY MANA

  • Fixed component ID

    5635FCP01

Applicable component levels

  • R510 PSY UA74274

       UP14/08/14 P F408