A fix is available
APAR status
Closed as program error.
Error description
SMPE receive of a large maintenance receives following abends: IEC031I D37-04,IGC0005E,jjj,sss,SMPPTS, dev,volser,dsname IEC032I E37-04,IGC0005E,jjj,sss,SMPPTS, dev,volser,dsname IEC143I 213-50,IGG0191B,jjj,sss,SMPPTS, dev,volser,dsname IEC032I E37-04 MSGIEC032I ABENDE37 RC04 IEC143I 213-50 MSGIEC143I ABEND213 RC50 IEC031I D37-04 MSGIEC031I ABENDD37 RC04 Logrec contains : S0F4 RSN050BC015 IGWIMF21 / IGWIRCMT No secondary allocation S0F4 RSN200B0033 IGWIMF21 / IGWIRCMT Unable to schedule IRB due to taskTERM S0F4 RSN050BC005 IGWIMF21 / IGWIRCMT No DASD space available 050BC015 200B0033 050BC005 PDSE/K
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Opening a PDSE which is completely full and * * can not be successfully full will result in * * S213-50 if the pdse has pending delete * * members. * **************************************************************** * PROBLEM DESCRIPTION: See Users Affected. * **************************************************************** * RECOMMENDATION: * **************************************************************** Modify the way IGWIRCMT handles out of space to prevent abend by OPEN when the PDSE is full.
Problem conclusion
See Problem Summary. KEYWORDS: PDSE/K
Temporary fix
********* * HIPER * ********* THE FULL DATA SET SHOULD BE COPIED TO A NEW BIGGER DATA SET.
Comments
APAR Information
APAR number
OA45400
Reported component name
EXTENDED DATA S
Reported component ID
5695DF115
Reported release
210
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2014-06-06
Closed date
2014-06-16
Last modified date
2014-09-15
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA73855
Modules/Macros
IGWIRCMT
Fix information
Fixed component name
EXTENDED DATA S
Fixed component ID
5695DF115
Applicable component levels
R210 PSY UA73855
UP14/08/01 P F407
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"210","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: