OA45258: IEC161I 215(00000008 660C012A 00000045 7F0A7200)-0801 OR IEC161I 215-0801 PERSISTS AFTER LOCK NAME CORRECTED

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as unreproducible in next release.

Error description

  • If the SMS LOCK SET contains an incorrect lock structure name,
    an OPEN will receive an IEC161I 215-0801. This is normal.
    
    If, however, the lock structure name is corrected, any
    subsequent OPEN will also receive the same message. NON-RLS
    open will also receive the same message because SMSVSAM
    continues to use the incorrect lock name which was stored in the
    VVR.
    
    IEC161I 215-0801
    IEC161I 215(00000008 660C012A 00000045 7F0A7200)-0801
    
    IDCAMS will also receive the IEC161I as well as IDC messages:
    IDC3300I  ERROR OPENING NB.RLS.TEST1
    IDC3351I ** VSAM OPEN RETURN CODE IS 191
    IDC3003I FUNCTION TERMINATED. CONDITION CODE IS 12
    
    So this APAR is to fix the SMSVSAM code to remove the lock
    structure name from the VVDS if the lock structure does not
    exist and the open fails.
    
    The documentation for CODE 191 should also be updated in both
    the IDC3351I documentation and the VSAM OPEN return codes in
    Macro Instructions for Data Sets.
    
    May also see logrec entries for an
    ABEND0F4 in IGWLNI01 with RC24 RSN66021231
    
    Additional keyworks:
    RLS SMSVSAM MSGIDIEC161I RLSABEND0F4
    

Local fix

  • VVR needs to be reset. This can be done via delete/redefine of
    the data set. If the data need to be preserved, you may be able
    to copy and restore the data via DSS DUMP / RESTORE.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All VSAM RLS users.                          *
    ****************************************************************
    * PROBLEM DESCRIPTION: IEC161I 215(00000008 660C012A 00000045  *
    *                      7F0A7200)-0801 or IEC161I 215-0801      *
    *                      persists after lock name corrected.     *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    If the SMS LOCK SET contains an incorrect lock structure name,
    an OPEN will receive an IEC161I 215-0801. This is normal.
    However, if the lock structure name is corrected, any
    subsequent OPEN will also receive the same message. NON-RLS
    open will also receive the same message because SMSVSAM
    continues to use the incorrect lock name which was stored in
    the VVR.
    

Problem conclusion

Temporary fix

Comments

  • The function/operation described is accepted as a future
    objective for a change in the base product design.
    SM02613
     KEYWORDS: RLSPSP/K
    

APAR Information

  • APAR number

    OA45258

  • Reported component name

    VSAM REC LEV SH

  • Reported component ID

    5695DF122

  • Reported release

    C10

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2014-05-22

  • Closed date

    2014-06-05

  • Last modified date

    2014-06-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    VSAM REC LEV SH

  • Fixed component ID

    5695DF122

Applicable component levels

  • RC10 PSN

       UP

  • RD10 PSN

       UP

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"C10","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
05 June 2014